Troubleshooting Guide
Important Safety Information 
4 333394L
Important Safety Information
The following warnings are for the setup, use, maintenance, and repair of this equipment. The 
exclamation point symbol alerts you to a general warning and the hazard symbols refer to 
procedure-specific risks. When these symbols appear in the body of this manual or on warning 
labels, refer back to these Warnings. Product-specific hazard symbols and warnings not 
covered in this section may appear throughout the body of this manual where applicable.
WARNING
GROUNDING INSTRUCTIONS
This product must be grounded. In the 
event of an electrical short circuit, 
grounding reduces the risk of electric 
shock by providing an escape wire for 
the electric current. This product is 
equipped with a cord having a 
grounding wire with an appropriate 
grounding plug. The plug must be 
plugged into an outlet that is properly 
installed and grounded in accordance 
with all local codes and ordinances.
•
Improper installation of the grounding plug 
is able to result in a risk of electric shock.
•
When repair or replacement of the cord or 
plug is required, do not connect the 
grounding wire to either flat blade terminal.
•
The wire with insulation having an outer 
surface that is green with or without yellow 
stripes is the grounding wire.
•
Check with a qualified electrician or 
serviceman when the grounding 
instructions are not completely understood, 
or when in doubt as to whether the product 
is properly grounded.
•
Do not modify the plug provided; if it does 
not fit the outlet, have the proper outlet 
installed by a qualified electrician.
•
This product is for use on a nominal 120V 
circuit and has a grounding plug similar to 
the plug illustrated in the figures.
•
Only connect the product to an outlet having 
the same configuration as the plug.
•
Do not use an adapter with this product.
ti3509b
WARNING
Extension Cords:
•
Use only a 3-wire extension cord 
that has a grounding plug and a 
grounding receptacle that accepts 
the plug on the product. 
•
An undersized cord results in a 
drop in line voltage and loss of 
power and overheating.When in 
doubt use the next heavier gauge. 
The smaller the gauge number the 
heavier the cord.
•
When using the sprayer outdoors, use an 
extension cord suitable for outdoor use.
•
Make sure your extension cord is not 
damaged. When using an extension cord, be 
sure to use a cord heavy enough to carry the 
current that your sprayer draws. See chart for 
appropriate sizes and lengths:
Extension Cord
Conductor Size Length
AWG (American 
Wire Gauge)
Metric Maximum
18 
1.0 mm
2
50 ft (15 m)
16 
1.5 mm
2
100 ft (30 m)
14 
2.5 mm
2
200 ft (61 m)