Specifications
Test Report
Number: GZHH00390347
Tests Conducted
*GZHJ390347*
Page 4 of 5
Intertek Testing Services Shenzhen Limited, Guangzhou Branch
帿㖕㣔牬餘ꆀ䪮助剪⸉剣ꣳⰖ䎛䊜ⴔⰖ
#111 TCL Cultural Industry Park, Guangpu-west Road, Science City, High and New Technology Industrial
Development Zone, Guangzhou. / Block E, No.7-2 Caipin Road, Guangzhou Science City, GETDD, Guangzhou.
䎛䊜넞倝䪮助䒓〄⼓猰㷖㙹⯕靶銯騟 69 〿 TCL 俒⻊❡⚌㔩宨瑟ꢂ 111/䎛䊜絑崸䪮助䒓〄⼓猰㷖㙹䕙곸騟 7 〿⛓✳ E 叿(510663)
Tel +8620 8213 9688
Fax +8620 3205 3537
intertek.com.cn
intertek.com
3 Total Lead (Pb) Content in Non-Surface Coating Materials (Substrate)
As per Standard Operating Procedures for Determining total Lead (Pb) in children’s products, test methods
CPSC-CH-E1002-08.3 and/or CPSC-CH-E1001-08.3 were used and total Lead content was determined by
Inductively Coupled Argon Plasma Spectrometry.
Result (ppm)
Tested Component
Element
(3+4), (5+6), (7+8), (9+10), (11+12)
Reporting
Limit
(ppm)
Limit
(ppm)
Lead (Pb) ND 10 100
The above limit was quoted according to U.S. Consumer Product Safety Improvement Act 2008 Title I,
Section 101 for total Lead content in Non-surface coating materials.
ppm = parts per million = mg/kg
ND = Not detected (less than reporting limit)
Tested components: See component list in the last section of this report
Remark: As requested by the applicant, the normal and reasonably foreseeably use and abuse test was not
conducted on the submitted sample.
4 Total Lead (Pb) Content in Surface Coating
As per Standard Operating Procedure for Determining Lead (Pb) in paint and other similar surface coatings,
test method CPSC-CH-E1003-09.1 was used and total Lead content was determined by Inductively Coupled
Argon Plasma Spectrometry.
Result (ppm)
Tested Component
Element
(1+2)
Reporting
Limit
(ppm)
Limit
(ppm)
Lead (Pb) ND 10 90
The above limit was quoted according to U.S. CFR Title 16 Part 1303 and U.S. Consumer Product Safety
Improvement Act 2008 Title I, Section 101 for total Lead content in surface coating.
ppm = parts per million = mg/kg
ND = Not detected (less than reporting limit)
Tested component(s): See component list in the last section of this report
Remark: As requested by the applicant, the normal and reasonably foreseeably use and abuse test was not
conducted on the submitted sample.
************************************************************************************************************************************