Owner`s manual

5
6. SIDECHAIN / LINK / NORMAL - This switch is to activate either a) linking of two m102’s for use in stereo
compression scenarios, or b) to activate external side chain control of the compressor for ducking, de-essing
etc, or c) for normal compressor operation.
7. OUTPUT - The output control provides 20dB of variable level control at the output of the m102, from -10dB
to +10dB. This control is useful for small level adjustments during tracking or for compression gain makeup.
8. POWER / OUT / IN SWITCH - This 3 position switch activates the power supply circuitry and engages the
compressor circuitry.
9. PEAK INDICATOR - The LED peak indicator, which monitors the signal at the output of the compressor,
illuminates green at -10dBu and red at +20dBu (6dB before clipping).
10. GR METER - This 10 segment meter displays the amount of gain reduction being applied to a signal in the
compression circuit.
Rearpanel Connections
PUSH
INPUTOUTPUT
STEREO LINK /
SIDECHAIN INPUT
GRACE DESIGN BOULDER, CO USA
100-240V
~
50-60Hz 7W max
RoHS
COMPLIANT
Pb
12
4
3
1. LINE INPUT - Balanced line inputs, XLR wired pin 2 positive, pin 3 negative and pin 1 ground, TRS wired tip
positive, ring negative, and sleeve ground.
2. LINE OUT - Balanced line outputs, XLR wired pin 2 positive, pin 3 negative and pin 1 ground, TRS wired tip
positive, ring negative, and sleeve ground.
3. STEREO LINK/ SIDECHAIN - This 1/4” input accepts either the connection from another m102 for linking
compressor controls for stereo use, or an external side chain signal source to control the compressor for
ducking or de-essing applications. In sidechain mode, the connection is unbalanced with only the tip
connected, so simply use an unbalanced 1/4” connector. Link mode requires a TRS 1/4” inch cable.
4. POWER SUPPLY - A universal input AC supply provides mains power to the m102. A standard three
prong AC power cable is included with the m102. For safety, the power supply cord must be
connected to a grounded outlet. The Disconnect Device for the m102 is the Mains plug or the
Appliance Coupler on the power supply cord. The Disconnect Device must remain accessible and operable.