SPECIFICATIONS
The M-3130 fuel pump is designed to safely transfer low vis-
cosity petroleum fuels such as gasoline, kerosene and diesel
fuel. The pump is designed for permanent mounting on vented
storage tanks, either in-ground or above-ground. RAINPROOF
for outdoor use.
Performance
Pump Rate: Up to 30 GPM (113 LPM)
Duty Cycle: 30 minutes ON, 30 minutes OFF
Dry Prime: 15 ft. (4.6m) maximum
Discharge Lift: 10 ft. (3m) maximum
Electrical
Input: Factory set at 115 VAC, 60 Hz. Optional
to set at 230 VAC, 60 Hz.
Conduit: 1/2 inch FNPT
Current Draw: 9.8 amps at full load (at 115 VAC, 60 Hz)
Motor: 3/4 HP, 1725 RPM induction type provided
with an internal auxiliary temperature-
limiting device
Mechanical Connections
Bung: 2 inch MNPT
Inlet: 1-1/4 inch FNPT
Outlet: 1 inch FNPT
Accessories
Hose: 1 in. x 12 ft. (3.7m) Buna-N electrically
conductive
Nozzle: 1 in. manual leaded spout or 1 in. auto-
matic diesel
Security: Nozzle can be padlocked
Ship Weight 69 lbs. (31 kg) - Pump only
77 lbs. (35 kg) - With manual nozzle
79 lbs. (36 kg) - With automatic nozzle
PARTS AND SERVICE
In order to preserve the UL Listing for pump safety, return the
entire pump to the factory for repair or replacement. For prod-
ucts serviced outside the factory, the UL nameplates must be
defaced to indicate that the equipment may no longer meet the
requirements for UL Listing. This does not apply to products
serviced outside the factory under the UL program for Rebuilt
Motors for Use in Hazardous Locations.
For warranty consideration, parts, or other service informa-
tion, please contact your local distributor. If you need further
assistance, contact the GPI Customer Service Department
in Wichita, Kansas, during normal business hours. A toll free
number is provided for your convenience.
1-800-835-0113
To obtain prompt, efficient service, always be prepared with
the following information:
1. The model number of your pump.
2. The manufacturing date code of your pump.
For the M-3130 series, the date code is located on the motor
nameplate.
For warranty work, always be prepared with your original sales
slip or other evidence of purchase date.
Please contact GPI before returning any pump. It may be pos-
sible to diagnose the trouble and find a solution with a telephone
call. GPI can also inform you of any special requirements you
will need to follow for shipping.
Do not return the pump without authority from the Cus-
tomer Service Department. Due to strict government
regulations, GPI cannot accept pumps unless they have
been drained and cleaned.
CAUTION
SAVE THESE INSTRUCTIONS