Product Manual
5
Activating the Meter
The computer is on continuously
and always ready to perform. The
computer is powered by off-the-shelf
field replaceable batteries. When
display becomes dim, faded or the low
battery message appears (see below),
the batteries need to be replaced.
Reference the Maintenance Section
for details.
Batch and Cumulative Totals
The computer maintains two totals. The
cumulative total provides continuous
measurement and cannot be manually
reset. The batch total can be reset
to measure flow during a single use.
The cumulative total is displayed on
the small display on the right, labeled
TOTAL. The batch total is displayed
on the large centered display and is
labeled BATCH TOTAL.
When the BATCH TOTAL reaches a
display reading of 999.9 and the next
rollover occurs, the floating decimal
adjusts to the right and the BATCH
TOTAL continues displaying in whole
units only.
Press and hold the RESET button for
about 3 seconds to reset the BATCH
TOTAL to zero.
Units
The unit of measure being dispensed
is displayed in the small display on
the left, labeled UNITS. The unit of
measurecanbechangedintheeld.
Factory Conguration
All units with NPT fittings leave the
factory configured for gallons. Units
with BSPP fittings leave the factory
Electronic
This meter is UL Listed as Intrinsically
Safe for Class1, Division1, Group D.
-29°C<Ta<60°C.
NOTE: The UL Listing only applies
to models with NPT threads.
Computer Display
Alloperationsarereectedinthethree
computer LCD readouts. The large
center display represents the batch
total for each fuel delivery. The small
display on the left represents the units
of measure being dispensed. The small
display on the right represents the cu-
mulative total of all fuel deliveries and
cannot be reset. The LCD display has
LED backlighting function that can be
turned on when needed for viewing in
low light or darkness.
Computer Buttons
The three buttons on the face of the
computer are used to perform their
labeled functions (noted below) and
other unlabeled functions described in
the Calibration Section.
LIGHT: Press and hold to illuminate the
backlight LCD display for viewing in low
light or darkness. Judicious use of this
feature will prolong battery life.
CAL: This button is used in the field
configuration and calibration proce-
dures described later in this manual.
RESET: Press and hold for about 3
seconds to reset the BATCH TOTAL
to zero. This button is also used in the
eldcongurationandcalibrationpro-
cedures described later in this manual.