Product Manual

15
ELECTRONICS
Standard Features Include:
2 Totalizing Registers
1 Factory Calibration Curve
1 Field Calibration Curve
7 Units of Measure (Selectable)
Units of Measure: US Gallons, Quarts,
Imperial Gallons, Barrels (42g), Litre,
Ounces & Pints
Special Order Units: Units of Measure: Cubic Centimeters, Cubic
Feet and Cubic Meters
Field Calibration Correction:
Minimum
Maximum
-99.9%
+99.9%
Readout Totals:
Batch Total
Cumulative Total
0.1 to 9999
1 to 999999
Pulse Signal Output: (Current Sinking)
NPN/Open Collector Frequency
10-100 Hz
Entity Paramerers: (For Safety Barrier)
Vmax(Ui)
Imax (
I
i)
Pmax (Pi)
6.8VoltsDC
200 mAmps
0.2 Watts
Ci
Li
15 uF
0 mH
Temperatures:
Operational
Storage
-20° F to +140° F (-29° C to +60° C)
-40° F to +158° F (-40° C to +70° C)
Power:
Internal Power Supply
4AALithiumBatteriesat1.5VoltsEach
Battery Life: 2-4 years
(Depends on frequency of backlight use)
NOTES: 1. Accuracy is factory calibrated using diesel fuel.
2. Cable strain relief and O-ring are supplied with every meter for pulse access.
SPECIFICATIONS
MECHANICAL
Flow Range 5 to 30 GPM / 19 to 114 LPM
Typical Accuracy ± 2%
Type Nutating Disc
Housing Material Aluminum
Maximum Working Pressure 50 PSIG / 3.4 bar
Inlet/Outlet Fitting Size 3/4", 1", or 1-1/2"
Threads NPT or BSPP
Approximate Ship Weight 8.0 lbs. / (3.63 kg)
Maximum Dimensions:
(In Top to Bottom Flow Conguration)
Width:
Height:
Depth:
6.6 Inches / (16.8 cm)
7.0 Inches / (17.8 cm)
6.1 Inches / (15.5 cm)