Product Manual
10
Clean or Replace Strainer:
1. Remove the nuts and bolts at the
inlet fitting. Remove the fitting,
O-ring, and strainer.
2. Using a fine brush, clean the
strainer. Replace the strainer as
necessary.
3. Wipe clean the inlet, housing,
and O-ring groove. Coat the
O-ring with oil or light grease.
Make sure the O-ring is fully
seated. Replace the strainer.
4.
Position the inlet fitting in the
desired orientation and torque
the nuts and bolts to 60-72 in-lb
(recommended) or until tight.
Electronic
The computer electronics is powered by
four AA size 1.5 volt lithium batteries.
WARNING
Use only
Energizer® L91 (Ultimate Lithium)
batteries.
● Type:Lithium/IronDisulde.
● Size:AA.
● Voltage:1.5V.
8. Adjust the cable so the jacket ends
at the bottom end of the strain relief
and tighten the domed top to envi-
ronmentally seal the cable entry.
9. Reinstall the computer display
back housing onto the computer,
ensuring the O-ring is securely
seated and no wires are pinched.
Tighten screws.
10. Reinstall batteries, ensuring the
O-ring is securely seated and no
wires are pinched. Tighten screws.
11. Reassemble computer display to
cover and tighten screws. Reattach
cover to meter body, running cable
through side slot in cover.
Reference 126340-01 drawing in this
manual and included with this product
for specifications regarding Safety
Barriers and their installation.
MAINTENANCE
Mechanical
The meter’s strainer should be cleaned
at regular intervals, especially when
lowowisdetected.
Black Common
COM
SIG
White Pulse Out
White
Signal
Black
Common
U.L. Listed
Intrinsic Safe
Barrier
Connector Diagram
Figure 8