Datasheet

Product Specification Model No.: GP11A
Document Number: BQS2202 Revision: 04 Page 2 of 3
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.
3. PERFORMANCE
Unless otherwise stated, tested should be done within one month of delivery under the following conditions:
Test Unit Specification
Conditions Remarks
Service life hr ≧ 74 10 K ohm load, cut-off voltage 3.0V
Eight batteries discharged to the end voltage,
calculate the average without the exclusion of
any result. No battery permit to go below 8% of
the service hours specified in the table. Only 1
retest is allowed for each lot tested.
Open Circuit Voltage
(OCV)
V ≧ 6 The open circuit voltage is measured on a
digital voltmeter with input impedance of 1
mega ohm minimum.
digital multimeter
Close Circuit Voltage
(CCV)
V
≧ 4.7
Load resistor 200 ohm for 0.1 to 2 seconds digital multimeter
Leakage
No leakage nor
deformation
When batteries are stored and discharge under
the standard conditions given in this document,
no electrolyte or other internal component shall
surfaces of the battery
naked eye
External Short
circuit
N/A No fire and no
explosion.
After standard charge, short circuit the cell
at 20±5
o
C until the cell temperature returns
to ambient temperature. (The resistance of
the inter-connecting circuitry shall not
exceed 0.1 ohm.)
4. CONFIGURATIONS, DIMENSIONS AND MARKINGS
Please refer to its Data Sheet.
5. EXTERNAL APPEARANCE
The cell shall be free from cracks, scars, breakage, rust, discoloration, leakage and deformation.
6. WARRANTY
Not less than 90% of the service capacity within first year, not less than 85% of the service capacity within third year
storage at 22 ± 3oC 40~80%RH.
7. Precaution, Handling and Storage
Ÿ Do not attempt to take batteries apart or subject them to pressure or impact. Heat may be generated or fire
may result. The alkaline electrolyte is harmful to eyes and skin, and it may damage clothing upon contact.
Ÿ Keep away from children. If swallowed, contact a physician at once.
Ÿ Do not mix GP batteries with other battery brands or batteries of a different chemistry such as alkaline and zinc
carbon.
Ÿ Do not short circuit batteries, permanent damage to batteries may result.
Ÿ Do not incinerate or mutilate batteries, may burst or release toxic material.