Datasheet

Product Specification Model No.: GPRHCH53D004
Document Number: TQS4829 Revision: 01 Page 3 of 5
Ambient Temperature, T
a
: 20 ± 5
Relative Humidity : 65 ± 20%RH
Notes: Standard Charge / Discharge Condition
Charge: 55mA (0.1C) ×16hrs
Discharge: 110mA (0.2C) to 2.0V
Test Unit Specification Conditions Remarks
Capacity mAh
550
Standard Charge / discharge Up to 3 cycles are
allowed
Open Circuit
Voltage (OCV)
V
2.5
Within 1hr after standard
charge
Internal
Impedance (Ri)
mΩ
172
Upon fully charge
At 1kHz
High Rate
Charge (0.5C)
mAh
485
Standard Charge, 1hr rest
before discharge
High Rate
Discharge (1C)
mAh
440
Standard Charge, 1hr rest
before discharge
Overcharge mAh No conspicuous
deformation and / or
leakage
55mA(0.1C) maximum current
charge for 1 yrs
Charge
Retention
mAh
440
Standard Charge,
Storage:12months at 20,
Standard Discharge
IEC Cycles Test Cycle > 500 IEC61951-2(2011) 7.5.1.2 (see Note 3)
Leakage N/A No leakage Fully charged at 550mA(1C),
Stand for 14 days.
External Short
Circuit
N/A No fire and no explosion After standard charge, short
circuit the cell at 20 ±5 until
the cell temperature returns to
ambient temperature. (The
resistance of the inter-
connecting circuitry shall not
exceed 0.1
Ω.)
Vibration
Resistance
N/A ΔV< 0.02V/cell
ΔRi (Internal
Impedance) < 5m
Ω/cell
Charge at 0.1C for 16 hrs, and
then leave for 24hrs,check
battery before / after vibration
Amplitude: 1.5mm
Vibration: 3000CPM
(any direction for 60mins)
Unit Cell
Impact
Resistance
N/A ΔV< 0.02V/cell
ΔRi (Internal
Impedance) < 5m
Ω/cell
Charge at 0.1C for 16 hrs, and
then leave for 24hrs,check
battery before / after drop
Height: 50cm
Thickness of wooden board:
30mm
Direction is not specified
Test for 3 times
Unit Cell
4. CONFIGURATIONS, DIMENSIONS AND MARKING