Dome Manual Dual Fuel

70
To wire the new probe, lift all the levers
on the left hand side up and insert the
wire into the holes on the side of the
junction. The pattern/colour of the wire
should match the corresponding wire on
the opposite side of the junction.
When the wire is fully inserted, push
the lever back to its original position to
clamp the wire in place. Ensure the wire
is fully clamped in place before moving
onto the next wire. Then reinsert the
terminal into the dock and ensure the
magnet engages with the metal plate.