2.21 Motor Controller Communication Codes
Code Message Limit Action
F-0884 Sequence code
Please shut o scooter and restart the ignition
with the kill switch in the “Oposition.
F-05C1
Battery Discharge
Indicator - Warning
SOC<3% - GO! S1.2/GO! S1.2+;
SOC<10% - GO! S2.4/GO! S2.4+
The operator should charge the battey. When
the battery is full charge the operator can
resume riding.
F-05C2
Battery Discharge Cut-out
- Warning
SOC<1%
The operator should charge the battey. When
the battery is full charge the operator can
resume riding.
F-05C3
Low Battery Voltage -
Warning
80V - GO! S1.2/GO! S1.2+;
56V - GO! S2.4/GO! S2.4+
The operator should charge the battey. When
the battery is full charge the operator can
resume riding.
F-05C4
High Battery Voltage -
Warning
114V - GO! S1.2/GO! S1.2+;
112V - GO! S2.4/GO! S2.4+
The operator should leave scooter in idle state
(ignition ON) for 2-3 minutes, battery balancing
in process.
F-05C5
Hight Capacitor Voltage -
Warning
114V - GO! S1.2/GO! S1.2+;
112V - GO! S2.4/GO! S2.4+
The operator should leave scooter in idle state
(ignition ON) for 2-3 minutes, battery balancing
in process.
F-05C6
Low Battery Voltage -
Warning
39.1V
The operator should charge the battery. When
the battery is fully charge the operator can
resume riding.