Spec Sheet
PAGE 3
Residential Water Systems
Goulds Water Technology
TWIN PIPE PERFORMANCE RATINGS
PACKER SYSTEM PERFORMANCE RATINGS
HP/Model ½ HP – J5 ¾ HP – J7 1 HP – J10 1½ HP – J15
Well Casing 2 3 2 3 2 3 3
Suction
Pipe Size (in.)
1¼ 1½ 1¼
1½
1¼
1½
1½
Jet Assembly
FP2-13 FP2-31 FP2-08 FP3-36 FP3-24 FP2-40 FP2-47 FP3-53 FP3-54 FP2-48 FP2-43 FP3-55 FP3-14 FP3-16 FP3-18 FP3-21 FP3-24
Package
➀
Jet Body (only) AP2 AP3 AP2 AP3 AP2 AP3 AP3
Nozzle
AN017 AN016 AN015 AN021 AN018 AN015 AN015 AN018 AN017 AN016 AN016 AN019 AN018 AN019 AN021 AN023 AN018
Venturi
AD726 AD723 AD720 AD730 AD724 AD727 AD723 AD730 AD725 AD729 AD725 AD732 AD727 AD735 AD723 AD731 AD724
Control Valve
30 30 30 30 30 30 32 27 30 35 36 28 32 34 34 34 39
Setting (PSI)
➁
Feet Gallons Per Minute (GPM) 30-50 PSI Pressure Switch Setting
30 11.9 9.5 13.1 13.8 16.8 16.7 19.3 24.4
40 10.6 7.9 12.6 13.5 16.8 14.6 19.3 23.1
50 7.6 10.7 6.9 11.5 15.3 13.5 18.0 20.2
60 6.7 4.8 8.8 6.5 9.0 7.8 13.5 11.0 9.2 15.3 16.9 15.0
70 4.3 7.3 5.6 7.1 11.5 9.8 9.0 12.7 14.4
80 3.5 4.8 5.1 8.6 7.3 10.2 10.3 12.9
90 4.3 7.3 5.6 8.8 10.9 10.3
100 6.2 4.2 7.2 9.6 7.3
110 5.0 5.8 8.2 6.5
120 4.5 6.9 5.8
130 5.8 5.0
140 4.7 4.5
150 3.4 4.0
160 3.3
170 2.8
NOTE: An offset of 50 feet will result in a decrease of about 25% from ratings as shown. Special turned (diameter) couplings are required on
2" packer systems, order no. 64655 in Jet and Sub price book.
➀ Jet Assembly Package includes jet body, AP2 or AP3; built-in check valve, nozzle and venturi.
➁ Same as above
Depth to Jet Assembly
(based on submergence of 5 feet)
HP/Model ½ HP – J5 ¾ HP – J7 1 HP – J10 1½ HP – J15
Well Casing min. I.D. 4 4½ 4 4½ 4 4½ 4½
Pressure 1 1¼ 1 1¼ 1 1¼ 1¼
Suction 1¼ 1½ 1¼
1½
1¼
1½
1½
➀
Jet Assembly Package
FT4-13 FT4-31 FT4-08 FT5-14 FT4-14 FT4-34 FT4-18 FT5-47 FT5-48 FT4-44 FT4-43 FT4-18 FT5-49 FT5-11 FT5-12 FT5-11
Jet Body (only) AT4 AT5 AT4 AT5 AT4 AT5 AT5
Nozzle
AN017 AN016 AN015 AN018 AN017 AN016 AN016 AN018 AN017 AN017 AN017 AN016 AN019 AN018 AN019 AN018
Venturi
AD726 AD723 AD720 AD724 AD729 AD725 AD722 AD730 AD725 AD730 AD727 AD722 AD732 AD727 AD734 AD727
➁
Control Valve Setting (PSI)
30 30 30 30 28 29 30 28 30 31 33 35 30 32 35 40
Feet Gallons Per Minute (GPM) 30-50 PSI Pressure Switch Setting
30 13.0 11.0 15.8 16.6 17.0 19.3 21.2
40 11.8 9.0 15.7 16.0 16.6 18.0 20.0
50 7.6 6.9 13.2 15.0 14.4 16.0 16.1
60 7.0 5.2 6.4 10.2 13.0 11.5 11.2 14.3 15.0
70 4.7 5.6 8.2 11.0 10.0 9.3 12.6 14.0 11.2
80 3.8 4.8 6.5 8.6 7.3 6.2 10.0 10.0 10.6
90 3.1 4.1 5.0 5.0 7.3 6.1 8.7 9.0
100 4.4 6.0 5.4 7.0 7.6
110 3.5 5.0 4.5 5.7 6.2
120 4.5 5.2
130 4.0
140 2.8
150 1.5
160
170
NOTE: An offset of 50 feet will result in a decrease of about 25% from ratings as shown.
➀ Jet assembly package includes jet body (AT4), venturi, nozzle and foot valve.
➁ Deep well jet pumps require a pressure control device on the discharge to provide back pressure to the jet assembly. Failure to control
the amount of discharge by adjusting the back pressure (pressure control valve setting) will cause the pump to lose prime. On pumps with
Iow control valve settings, up to 40 psi, a simple ball valve or AV15 will work. On systems with control valve settings of 40 - 80 psi an AV22,
AV22KIT or AV21 is required. They measure the pressure on the outbound side so that the high pressure does not open the 30-50 psi
switch and turn the pump off.
Pipe
Size (in.)
Depth to Jet Assembly
(based on submergence of 5 feet)