Spec Sheet
PAGE 2
Residential Water Systems
Goulds Water Technology
SHALLOW WELL PERFORMANCE RATINGS
HP/Model ½ HP – J5 ½ HP – J5 ¾ HP – J7 1 HP – J10 1½ HP – J15
Shallow Well
FH5 FH5H (High Pressure Model) FH7 FH10 FH15
Package
Adapter 4K62
Nozzle AN017 AN019 AN018 AN018 AN022
Venturi AD3731 AD3528 AD3536 AD3538 AD3542
Discharge Pressure – PSI Discharge Pressure – PSI Discharge Pressure – PSI Discharge Pressure – PSI Discharge Pressure – PSI
20 30 40 50 20 30 40 50 60 30 40 50 60 30 40 50 60 30 40 50 60
5 17.5 16.5 10.2 5.0 63 11.5 11.3 11.0 7.7 4.8 83 21.3 18.3 12.5 6.6 70 24.8 24.4 16.6 9.9 74 26.6 26.3 25.0 15.6 80
10 15.7 14.4 9.2 4.3 61 10.3 10.0 9.6 7.0 4.2 81 18.8 17.3 11.3 5.0 68 22.9 22.2 15.8 8.6 72 24.7 24.3 22.6 13.9 77
15 13.7 12.5 8.0 3.6 59 8.8 8.6 8.3 6.3 3.7 79 16.4 15.5 9.6 3.7 66 19.8 19.5 13.8 6.9 70 21.6 21.5 20.4 12.9 75
20 11.5 10.4 7.1 2.3 57 7.0 7.0 6.8 5.8 3.2 76 13.6 13.2 8.3 2.0 63 16.6 16.6 12.2 5.6 67 18.1 18.0 17.6 12.0 73
25 8.7 8.6 6.2 1.3 54 5.3 5.2 5.2 5.0 2.8 73 10.0 9.9 6.4 1.0 59 12.5 12.4 10.4 3.6 65 14.0 14.0 14.0 10.1 71
Gallons per minute
Max.
Shut
off
(PSI)
Gallons per
minute
Max.
Shut
off
(PSI)
Gallons per
minute
Max.
Shut
off
(PSI)
Gallons per
minute
Max.
Shut
off
(PSI)
Max.
Shut
off
(PSI)
Total Suction
Lift (feet)
Gallons per
minute
APPLICATIONS
Specically designed for:
• Homes
• Farms
• Cottages
• Booster service
SPECIFICATIONS
Pump:
• Pipe connections: 1¼" NPT suction, 1" NPT dis-
charge,
1" NPT drive (pressure)
• Pressure switch: AS4 preset at 30-50 PSI
Motor:
• NEMA standard
• 60 Hz
• ½ – 1½ HP, 115/230 V capacitor start
• Single phase
• 3500 RPM
• Built-in overload with automatic reset
• Stainless steel shaft
• Rotation: clockwise when viewed from motor end
• UL778 listed
Maximum temperature: 140°F
SYSTEM COMPONENTS
• Basic Pump Unit: Includes pump and motor, pres-
sure gauge and bushing, pressure switch with tub-
ing and ttings.
NOTE: THE TUBING COMES CONNECTED FOR
SHALLOW WELL USE. A DEEP WELL SET UP RE-
QUIRES A JDW FITTINGS PACKAGE OR AN AV22
KIT.
Both include additional ttings and a 24" tubing to
connect to a pressure control valve.
ADDITIONAL COMPONENTS REQUIRED
• Shallow Well Package: Includes shallow well adapter,
nozzle, venturi (diffuser), gasket, bolts
and pipe plugs OR
• Deep Well Package: Choose either a twin pipe or
packer style.
• Twin pipe includes jet body, nozzle, venturi (dif-
fuser) and foot valve.
• Packer includes packer body, nozzle, venturi (dif-
fuser), and built-in check valve.
NOTE: Packer systems also require a packer adapter
on the wellhead.
Deep well systems require a pressure control valve.
NOTE: YOU MUST HAVE A JDW OR AV22 KIT TO
MAKE THE PRESSURE SWITCH CONNECTION.
Pressure tank required on all systems.
MODEL INFORMATION
CSA Listed U.L. Listed (Indoor use)①
HP
Order No. Order No.
J5 J5UL ½
J7 J7UL ¾
J10 J10NUL 1
J15 J15UL 1½