Instructions / Assembly

Table Of Contents
en Original Instructions
Installation, Operation and Maintenance Manual 29
5. Cable installation:
Insert the cable through the threaded
hole into the motor housing.
Push the lever of the terminal block
with a flat screw driver and get each
stripped core into the proper hole.
Take care of matching the markings
of
the terminal block with the
proper
cable colors.
The whole stripped conductor length
must be inside of the terminal block.
Insert the cable gland components
into the housing and tighten the nut.
6. Final assembly:
Put the end cap back to the motor
housing.
Take care of its orientation, only one
angular position is correct.
Tighten the screw (~5.3 lb-in / 0.6 Nm).
DANGER: Electrical hazard
Be certain that all connections are secure and the conduit box cover is closed before electrical
power is connected.
DANGER: Electrical hazard
P
umps, that do not equipped with standard power supply plug
, may only be connected to the
electrical system in a separate
protective box. For identification, check the 8
th
character of the
technical code
(counting after the prefix “E5-“) of the product (see item
10
on
Figure 1
on page
12
)
,
codes C, S, and X are affected.
NOTICE:
Before the electrical connection is energized, the pump unit must be filled with water; if not, the
bearings will be destroyed by dry operation.
4.4.3 Guidelines for timer connection
1. Follow the steps
1
. to
5
. of section
4.4.2
2. Connect the 3-
pin connector of the
timer into the proper opening of the
motor housing.
3. Final assembly:
Put the timer to the motor housing.
Take care of its orientation, only one
angular position is correct.
Tighten the screw (~5.3 lb-in / 0.6 Nm).