Replacement Parts List

PAGE 16
Wastewater
Goulds Water Technology
CAPACITOR DATA
"K" no. MFD VAC
9K197 161/193 110
Wt.
(lbs./5 ft.)
Type and
AWG Size
458
484B
456
Group
457
341
112A
112B (Upper)
412M
371C
383
361D
351
412P
358
387
304
100
351
352
101
184
340
372D
338
378
484
455A Group
358E
246
MODEL 2ED
Item No. 456, Power Cables
Standard length Optional Lengths
20' 30' 50' 100'
1 PH:
1
3
HP, 115 V; standard with plug, optional lengths have bare leads. SJTOW – 16/3 9K165 9K214 9K215 N/A 0.5
1 PH: ½ HP, 115 V; standard with plug, optional lengths have bare leads. STOW – 14/3 9K385 - SJTOW 9K216* 9K161* 9K217* 0.9
1 PH:
1
3
& ½ HP, 208 & 230 V; standard with plug, opt. lengths have bare leads. SJTOW – 16/3 9K164 9K214 9K215 N/A 0.5
1 PH: ¾ – 1½ HP, 208 & 230 V with bare leads. STOW – 14/3 9K163 9K216 9K161 9K217 0.9
3 PH: ½ – 1½ HP, 200–230/460/575 V with bare leads. STOW – 14/4 9K153 9K218 9K154 9K219 1.1
Item No. 455A, Sensor Cables
Mechanical Seal Sensor - Standard for All Models SJTOW – 16/2 9K189 9K220 9K221 9K222 0.5
Mechanical Seal/Heat Sensor - Optional for 3-Phase Models SJTOW – 18/4 9K237 9K238 9K239 9K240 0.5
* Requires 5K111 Strain Relief Assembly and 1K208 Motor Cover.