3. SPECIFICATIONS
METRAFLEX 3000
METRAFLEX 3001
METRAFLEX 3003
METRAFLEX 3001XL
METRAFLEX 3003XL
Measuring ranges 30A 300A 3000A 30A 300A 3000A
Scaling factor 10 100 1000 20 200 2000
Output sensitivity 100mV/A
10mV/A 1mV/A 50mV/A 5mV/A 0,5mV/A
Accuracy (45-65Hz) ±1% of rdg.
±0,1A
±1% of rdg
.
±1A
±1% of rdg.
±0,1A
±1% of rdg.
±1A
Noise 8 mVrms
2 mVrms 8 mVrms
2 mVrms
Output Connector 1 pair 4mm safety plugs 4 pin Hypertronics plug
2x AA MN1500 LR6 Alkaline
2000 hrs (M’FLEX 3000/3001)
1000 hrs (M’FLEX 3003)
2x AA MN1500 LR6 Alkaline
2000 hrs (M’FLEX 3001XL)
1000 hrs (M’FLEX 3003XL)
3,5…12VDC/max. 100mA 2…3VDC/max. 100mA
Power Supply
Battery
Battery Life (typ.)
external*
)
Connector*
)
Barrel plug socket 5,5/2,1mm
minus at center pin
Barrel plug socket 5,5/2,1mm
minus at center pin
*) not available for METRAFLEX 3000
Output load 100 k for specified accuracy
Frequency range 10 Hz to 20 kHz (-10% attenuation)
Phase angle error (45-65Hz)
Position sensitivity ±2% of reading
External field ±0.2% of range with cable >200mm
(8") from the probe
Temperature coeff. ±0.1% / °K
Low battery Indicated by an orange LED
Overload Indicated by a red LED