6 Menu Structure and Parameters
Main menu level Submenu level Parameters level Parameters level
Display A Display B Display A Display B Display A Display B Display A Display B
setvp devic devic limit vl_l 0.0 . 00 vl_h 60. . 000
SETUP DEVICE Limit value parameter Voltage setting limit value, L = lower, U = upper
Setup menu
devic ovp ovp on ovdly 0.0 . 00
Overvoltage menu Overvoltage protection on/off Overvoltage delay time
devic oCp oCp off oCdly 0.0 . 00
Overcurrent menu Overcurrent protection on/off Overcurrent delay time
devic Cfg_d pon rst sset off
Device settings after power on
setvp dpy1f dpy1f dpy dpy-a vo dpy-b 1o
SETUP DISPLAY & INTERFACE
Digital display settings
Display A – standard display: Uo Display B – standard display: Io
Display and interface menu
dpy1f an1f trg-1 off trg-2 off
Analog interface settings Trigger input 1 on/off Trigger input 2 on/off
dpy1f bvs addr 12 bavd 9600
Interface settings Device address Transmission speed
setvp seq seq ctrl seq go seq hold
SETUP SEQUENCE Access sequence
Start sequence (RUN),
footnote 3
Stop sequence
Sequence menu
seq Cond i seq-n 0 Strt 0097
Sequence settings
Sequence no. (subsequence)
footnote 1
Start address
seq ed it mem-a 0100 vset 39 . 000
Edit sequence Voltage setpoint
seq mem load 0105 store 0105
Memory functions Load sequence Save sequence
setvp meas meas mm-v1 mm-v1 off v_ 9 . 992
SETUP MEASUREMENT EXTREME MEASUREMENT Min-Max memory
Minimum measured voltage value
Measuring menu
meas v1-Cs meas v1_Cs vc_ 0 . 000
meas Cfg_m m-lp 3 m-tab
meas spec
rl0ad
footnote 5
30. .531
Avx 1nfo l-Err 000 era 3
AUXILIARY Events and status memory Last error no. Events memory A
Memory and calibration menu
vers1 rel 01 . .001 vpd no
Firmware revision Firmware version Firmware update
adjvs 7.10.11 voff # vfs #
Balancing routine
Balancing date
Voltage setpoint zero point Voltage setpoint
upper limit
Y
Z
MENU
Y
Z
Y
Z
Y
Z
Y
Z
Y
Z
ESC
ESC
ESC
ESC
ESC
ESC
ESC
ESC
ESC
ESC
A
B
7
6
5
4
2
Y Z
vl_h 60000
Set parameter (example: upper limit value for voltage setpoint)
vl_h 60000
Y Z
Select entry position (decimal place).
Acknowledge selection.
vl_h 40000
Y
Z
Increase/decrease value – alternative:
vl_h 40000
Acknowledge parameter
ESC
Jump back to higher menu level.
A
ovp off
Select parameter – switch function on/off.
Acknowledge selection.
ovp on
Select status
ovp on
Acknowledge parameter.
B
Y
Z
(here: off, on, r01 ... r12).
Number blinks, NUM LED key lights up.
Enter value directly with the numeric keypad.
or abort procedure with
ESC
setup seq
LED display (display A / B)
Key
Parameter not yet set
Y Z
Scroll within the parameters level.
Select submenu or parameters level.
ESC
Jump back to higher menu level.
setup seq
#
Setting value is displayed, after which the
6
Hot key for direct parameter selection
measured value is entered and acknowledged with .
Select parameters.