User manual

12 GMC-I Gossen-Metrawatt GmbH
4 Technical Data
4.1 General Data
Output
Regulator type Primary switched-mode regulator
Operating modes Adjustable constant voltage / constant cur-
rent source with automatic sharp transition
Output insulation Floating output with “safe electrical
separation” from the mains input and
computer interfaces
Allowable potential,
output–ground Max. 240 V DC
Capacitance, output–ground (housing)
SYSKON P1500 series
Typically 1000 nF
Output Operating Ranges, Characteristic U-I-P Curve
Analog Interface
Functions – Auto-sensing mode
– 2 programmable trigger inputs
– 3 programmable signal outputs
– Voltage control input (0 ... 5 V)
– Current control input (0 ... 5 V)
– Voltage monitor output (0 ... 10 V)
– Current monitor output (0 ... 10 V)
– Master-slave parallel operation
– Master-slave series operation
– Auxiliary power output: 15 V / 60 mA
Computer Interfaces
IEC-625 / IEEE 488 interface (optional)
RS 232 interface
Transmission mode Half-duplex, asynchronous
Transmission speed 1200 to 115,200 baud, adjustable
•USB port
USB port: 4-pin, type B
USB 1.1 compatible with USB 2.0
Connector pin assignments 1: VCC, 2: D-, 3: D+, 4: GND
Transmission speed 9600 to 115,200 baud, adjustable
Power supply
Line voltage
115
/230 V ~ + 10 / – 15%; 47 to 63 Hz
Inrush current Max. 50 A
S
Mains fuse 1 x M 15 A / 250 V
(6.3 x 32 mm), UL
Electrical Safety
Safety class I
Measuring category II for mains input
I for output and interfaces
Fouling factor 2
Earth leakage current < 2.5 mA
RMS
Electrical isolation Test voltage
Output – mains 2.2 kV ~
Output – bus/ground 1.4 kV ~
Mains – bus/ground 2.2 kV –
Bus – ground No electrical isolation
Applicated Standards
IEC 61 010-1: 2001
DIN EN 61 010-1: 2001
VDE 0411-1: 2002
EN 61326
Electromagnetic Compatibility
Generic standard EN 61326-1: October 2006
Interference emission EN 55022: class B
EN 61000-3-2
EN 61000-3-3
Interference immunity
EN 61000-4-2: feature A
EN 61000-4-3: feature B
EN 61000-4-4: feature A
EN 61000-4-5: feature A
EN 61000-4-6: feature A
EN 61000-4-8: feature A
EN 61000-4-11: feature A
Ambient Conditions
Temperature range Operation: 0 to 40° C
Storage: –25 to +75° C
Atmospheric
humidity Operation: 75% rel. humidity,
no condensation allowed
Storage: 65% rel. humidity
Cooling With integrated fan
(temperature controlled)
Inlet vent: Side panel
Outlet vent: Rear panel
Operating noise Noise pressure level at a distance of 30 cm
with fan set to low / high
Front 17 / 28 dBA
Rear 22 / 32 dBA
Left 17 / 28 dBA
Right 20 / 31 dBA
Leistungskennlinie PSP 1500-60-60
25,0 A
60,0 V
60,0 A
25,0 V
12,5 A
60,0 V
60,0 A
12,5 V
0
10
20
30
40
50
60
70
0 10203040506070
Ia / A
Ua / V
230 VAC: 1500 W
115 VAC: 750 W
Characteristic Power Curve