Datasheet
SECUTEST BASE / PRO and SECULIFE ST BASE
Test Instruments for
Measuring
Electrical Safety of Devices
10 GMC-I Messtechnik GmbH
Customizable Test Instruments
Please note:
When ordering via features, please do not fail to quote the com-
plete order number (not the standard model).
Features with selection option
o „available“ can be freely selected.
Only one selection is possible per feature character.
Order example SECUTEST PRO:
M7050 AA03 B03 C07 E01 G01 H01 I01 KB01 P01
(highlighted features (printed in bold letters here, shaded in grey in
the table) are part of the SECUTEST PRO standard equipment that
cannot be modified. The other features can be freely selected).
AA02: Device Variant SECUTEST BASE10
C01: Language for user interface
, keyboard layout
and test sequences in Englisch
G01:
R-PE test current for protective conductor measurement:
200 mA und 10 A
SECUTEST BASE and SECUTEST PRO (List of Features)
1
10 A R
PE
measurements are only possible with line voltages of 115/230 V and line frequencies of 50/60 Hz.
Testers / Features Selection Option
Article Number/
Feature
Device Variant M7050
SECUTEST BASE (M7050 AA01 E00 G00 H00 I00 KB00) o AA01
SECUTEST BASE10
(M7050 AA02 E00 G01 H00 I00 KB00)
o AA02
SECUTEST PRO (M7050 AA03 E01 G01 H01 I01 KB01) o AA03
Connections – mains plug and test socket, each country specific
Germany with connection and safety class recognition o B00
UK o B01
CH o B02
FR/CZ/PL o B03
China o B04
USA o B05
AUS o B06
DK o B07
IT o B08
CH with connection and safety class recognition o B09
FR/CZ with connection and safety class recognition o B10
Language for preset user interface (preset language ex factory, can be changed subsequently to any of the languages listed
below)
German o C00
English o C01
French o C02
Italian o C03
Spanish o C04
Czech o C05
Dutch o C06
Polish o C07
Data entry via touch screen
without n AA01, AA02 E00
with n AA03 E01
R-PE test current for protective conductor measurement
200 mA n AA01 G00
10 A
1)
n AA02, AA03 G01
Connection for 2
nd
test probe
without n AA01, AA02 H00
with n AA03 H01
Function DVM (digital voltmeter) with 2 additional measuring inputs COM–V
without n AA01, AA02 I00
with n AA03 I01
Database expansion without n AA01, AA02 KB00
with n AA03
o AA01, AA02 KB01
Bluetooth
®
without n AA01, AA02, AA03 M00
with o AA01, AA02, AA03 M01
DAkkS calibration certificate (language combination)
in German, English and French o P00
in German, English, Polish o P01
in German, English, Italian o P02
DAkkS calibration certificate (recalibration) o
Key: n preset o available