Electrical Data, Series 320 W
If not otherwise specified, all entries are maximum values and are valid for an operating temperature range of 0 to 50 °C,
nominal power range and a line voltage range of 230 V ± 10% after a warm-up period of 30 minutes.
1) Typical values are increased by a factor of approximately 1.2 in the functional line voltage input range of –10% to –15%.
Description (abbreviated designation) SLP 320-32
Type 32 N 32 R 18
Nominal Output Data Voltage setting range 0 ... 32 V
Current setting range 0 ... 18 A
Continuous power where Tu 40 °C max. 320 W
Intermittent power where t < 90 s / Tu 25 °C max. 430 W
Current derating where Tu > 40 °C – 0.5 A / K
Output Operating Characteristics
Overall setting accuracy at 23 ± 5 °C
with reference to 3½ place setpoint display
including system deviation, load / mains
Voltage
Current
0.2% + 150 mV
0.5% + 50 mA
Static system deviation
1)
at 100% load variation
1)
Voltage
Current
30 mV
40 mA
Static system deviation
1)
at 10% line voltage variation
1)
Voltage
Current
10 mV
20 mA
Residual ripple
1)
Ua > 5% U
nom
Voltage (10 Hz ... 10 MHz)
Current (10 Hz ... 1 MHz)
30 mV
eff
50 mA
eff
(Ua > 10%U
nom
)
Common-mode noise (10 Hz ... 1 MHz) 0.5 mA
eff
Settling time (voltage)
with sudden load variation of 10 ... 90% I
nom
Tole ran ce
(Typical values) Δ I = 80%
64 mV
500 μs
Under and overshooting with sudden load variation of
50 A / ms
(Typical values) Δ I = 80% 450 mV
Settling time (voltage)
with setpoint jump: 0 100%
with setpoint jump: 100% 0
Tole ran ce
no load / nominal load
no load / nominal load
64 mV
1 ms / 1 ms
1 ms / 1 ms
Settling time (current)
with setpoint jump: 0 100%
with setpoint jump: 100% 0
Tole ran ce
short-circuit / nominal load
short-circuit / nominal load
180 mA
< 5 ms / < 5 ms
< 5 ms / < 5 ms
Measured Value Displays (3½ place)
Measurement resolution Voltage
Current
100 mV
10 mA
Measuring accuracy at 23 ± 5 °C
with reference to the respective measured value
Voltage
Current
0.2% + 120 mV
0.5% + 40 mA
Protective Functions
Output overvoltage protection Threshold 40 ± 1 V
Reversed polarity protection – overload capacity Continuous 20 A
Reverse flow resistance Continuous 64 V
General
Power supply
1)
Line voltage 230 V~ +10 / 15%
47 ... 63 Hz
Power Consumption At nominal load
In standby mode
At max. intermittent power
650 VA, 460 W
50 VA, 15 W
770 VA
Efficiency At nominal load > 69%
Switching frequency Typical 200 kHz
Article number K234A