User manual

20 GMC-I Gossen-Metrawatt GmbH
5.6 Voltage Monitoring Output
Function
The U-MON terminal, with reference to AGND, supplies a voltage
U
MU
which is proportional to Uout.
U-MON is used as a control voltage for series master-slave
connection (see 5.9.2).
U-MON can also be used for external measuring, monitoring and
recording purposes.
The following applies:
U
MU
= Uout k
MU
k
load
= 0 ... 10 V
k
MU
= 10 V / Uout
nom
, U monitor coefficient
R
i (U-MONITOR)
= 9.8 kΩ, U monitor internal resistance
Load Coefficient
R
load
= load resistance
Max. error, U
MU
: ± 5 mV ± 2% actual value (where R
load
> 10 MΩ)
Notes
U-MON is not potential-free, its reference point AGND is
connected to the negative pole of the output.
Connecting grounded measuring circuits to the monitoring output
may lead to erroneous measurements due to leakage current or
earth loops.
The voltage monitoring output makes reference to output
voltage acquired by the sensing leads (see chapter 2.3).
The monitoring output is short-circuit proof.
Internal resistance is equal to 9.8 kΩ.
Figure 5.6 Voltage Monitor Wiring
5.7 Current Monitoring Output
Function
The I-MON terminal with reference to AGND supplies a current U
MII
which is proportional to Iout.
I-MON is used as a control voltage for parallel master-slave
connection (see 5.8.2 and 5.8.3).
I-MON can also be used for external measuring, monitoring and
recording purposes.
The following applies:
U
MI
= Iout k
MI
k
load
= 0 ... 10 V
k
MI
= 10 V / Iout
nom
, I monitor coefficient
R
i (I MONITOR)
= 9.4 kΩ, I monitor internal resistance
Load Coefficient
R
load
= load resistance
Max. error, U
MI
:
±
5 mV
±
2% actual value (where R
load
> 10M
Ω
)
Notes
I-MON is not a potential-free, its reference point AGND is
connected to the negative pole of the output.
Connecting measuring current circuits to the monitoring output
may lead to erroneous measurements due to leakage current or
earth loops.
The monitoring output is short-circuit proof.
Internal resistance is equal to 9.4 kΩ
Figure 5.7 Current Monitor Wiring
k
load
R
load
R
load
9.8 kΩ+
---------------------------------------=
SLP-KONSTANTER
+SENSE
+OUT
-OUT
-SENSE
Analog Interface
SIG1 OUT
SIG2 OUT
TRG IN +
TRG IN -
+ 15 V
AGND
Uset -
Uset +
Iset +
U-MON
I-MON
Uout
Load
I
out
Settings
USET = Uset
ISET = Iset
OUTPUT on/off
-OUT
+OUT
V
U
MU
+
OUTPUT
R
load
k
load
R
load
R
load
9.4 kΩ+
---------------------------------------=
SLP-KONSTANTER
+SENSE
+OUT
-OUT
-SENSE
Analog Interface
SIG1 OUT
SIG2 OUT
TRG IN +
TRG IN -
+ 15 V
AGND
Uset -
Uset +
Iset +
U-MON
I-MON
Settings
USET = Uset
ISET = Iset
OUTPUT on/off
-OUT
+OUT
U
out
Load
I
out
V
R
load
U
MI
+
OUTPUT