Datasheet
SECUTESTBASE, BASE10 and XTRA
Test Instruments for
Measuring
Electrical Safety of Devices
2 GMC-I Messtechnik GmbH
Overview of Features Included with SECUTEST B
ASE
, B
ASE
10 and X
TRA
Test Instruments
1
10 A R
PE
measurements are only possible with line voltages of 115/230 V and line
frequencies of 50/60 Hz.
Display with Selectable Language
The display panel consists of a backlit, color multi-display at
which menus, setting options, measurement results, instructions
and error messages, as well schematic and wiring diagrams
appear.
The display and user prompting can be set to the desired lan-
guage depending on the country in which the test instrument is
used.
Data Entry
Data can be entered, for example, via a barcode reader con-
nected to the USB port, a USB keyboard, or via the softkey key-
board when it appears at the display.
Creating a Database
A complete test structure with data regarding customers and test
objects can be created in the test instrument. This structure
makes it possible to assign single measurements or test
sequences to devices under test belonging to various customers.
Manual single measurements can be grouped together into a so-
called “manual sequence”.
Data Interfaces
Structures set up in, and measurement data saved to the test
instrument can be imported to ETC report generating software via
the USB slave port. Data can then be archived at the PC, com-
ments can be added with the software and reports can be gener-
ated.
The following input and output devices can be connected to the
two integrated USB master ports:
• An external keyboard and a barcode reader
•A printer
Software Update
The test instrument can always be kept current thanks to firm-
ware which can be updated via the USB slave port. Software is
updated during the course of recalibration by our service depart-
ment, or directly by the customer.
Switch
Setting
Meas.
Variant
Measuring Function,
Test Current/Voltage
Single measurements, rotary switch level: green
Measurements at voltage-free objects
R
PE
R
PE
Protective conductor resistance
I Protective conductor current (200 mA)
SECUTEST B
ASE10/XTRA: 10 A
1
RISO
PC I
PC II
R
ISO
Insulation resistance
U
ISO
Test voltage
Measurements at DUTs with line voltage
I
PE
DIR
DIF
ELC
I
PE
Protective conductor current, RMS value
I
PE~
AC component
I
PE=
DC component
U
LN
Test voltage
IB
DIR
DIF
ELC
I
T
Touch current, RMS value
I
T~
AC component
I
T=
DC component
U
LN
Test voltage
IG
DIR
DIF
ELC
I
E
Device leakage current, RMS value
I
E~
AC component
I
E=
DC component
U
LN
Test voltage
IA
DIR
ELC
I
A
Leakage current from the
application part
U
A
Test voltage
IP
DIR with
probe
I
P
Patient leakage current, RMS value
I
P~
AC component
I
P=
DC component
U
LN
Test voltage
U
U
Probe voltage, RMS
U
~
Alternating voltage component
U
=
Direct voltage component
tA
t
B
PRCD time to trip
for 30 mA PRCDs
U
LN
Line voltage at the test socket
P Function test at the test socket
I Current between L and N
U Voltage between L and N
f Frequency
P Active power
S Apparent power
PF Power factor
Probe measuring functions
EL1
Extension cords with EL1 adapter:
continuity, short-circuit, polarity (wire reversal)
EXTRA
Reserved for expansion during the course of software updates
Key
DIR = direct measurement,
DIF = differential current measurement,
ALT = alternative measurement (equivalent leakage current
measurement)
Switch
Setting
Standard Measurement Type, Connection Type
Automated test sequences, rotary switch level: orange
Preconfigured (freely configurable) test sequences
A1
VDE 0701-0702 Passive measuring method, test socket
A2
VDE 0701-0702 Active measurement type, test socket
A3
VDE 0701-0702
Parameters configuration for EDP (active)
A4
IEC 62353 (VDE 0751) Passive measurement type
A5
IEC 62353 (VDE 0751) Active measurement type
A6
IEC 60974-4 Connection type: test socket
A7
IEC 60974-4 Connection type: AT16-DI/AT32-DI
A8
VDE 0701-0702
Messart Verlängerungsleitung
(RPE, RISO), Adapter EL1
AUTO
Freely selectable stan-
dard
Freely selectable measurement type and connec-
tion type