Operation Manual
72 GMC-I Messtechnik GmbH
Automatic Test – Individual Test Sequences
6 Automatic Test – Individual Test Sequences
6.1 Index Card System
Automated test sequences are run automatically after tapping the
ONSTART button in the “Automatic Test” menu.
Various options are provided for the selection of test sequences
via the “Test”, “Sequences”, “Objects” and “Deadlines” index
cards.
• Enter the ID number in the “Test” index card.
• Select a sequence form the “Sequences” index card.
• Select an object from the “Objects” index card.
• Select a deadline from the “Deadlines” index card.
You can change from one index card to the other by tapping the
appropriate tabs. The tab of the respectively selected index card
appears bright blue.
“Test” Index Card
After an ID number has been entered, all relevant test data for the
respective device under test is displayed.
“Sequences” Index Card
Test sequences which are available for a given object type are
listed in the “Sequences” index card. After a test sequence has
been selected, the “Test” index card is activated automatically.
“Objects” Index Card
All DUTs belonging to a given customer are listed in the “Objects”
index card according to location. After a device under test has
been selected, the “Test” index card is activated automatically.
“Deadlines” Index Card
All existing deadlines are listed here (section 7.5.2). When a dead-
line is selected, the Test index card is activated automatically and
the test data are displayed. The test can be started by tapping the
ONSTART button.
6.2 Prerequisites for the Test Sequence
• Deadline administration: If required, deadlines can be specified
here for periodic testing (see page 109).
• Object administration: The effected device under test must be
previously defined with an ID number along with its attributes
and test sequences (see page 94).
Auto-Test