GMC-I Messtechnik GmbH 137
Appendix
0701-0702 aktiv SK I + II 0701-0702 aktiv SK II 0701-0702 passiv SK I 0701-0702 passiv SK I + II 0701-0702 passiv SK II
Visual inspection Visual inspection Visual inspection Visual inspection Visual inspection
Contact exposed conductive parts of the
DUT which are connected to the protec-
tive conductor (PE) with the probe
(socket 1/2).
Contact exposed conductive parts of
the DUT which are connected to the
protective conductor (PE) with the
probe (socket 1/2).
Contact exposed conductive parts of
the DUT which are connected to the
protective conductor (PE) with the
probe (socket 1/2).
R-PE / Pd 0,25 / GW 0,3 R-PE / Pd 0,25 / GW 0,3 R-PE / Pd 0,25 / GW 0,3
R-ISO / SK1 500 / GW 1M
R-ISO / SK1 500 / GW 1 M
R-ISO / SK1 500 / GW 1 M
Contact exposed conductive parts of the
DUT which are
not
connected to the
protective conductor (PE) with the probe
(socket 1/2).
Contact exposed conductive parts of
the DUT which are
not
connected to
the protective conductor (PE) with the
probe (socket 1/2).
R-ISO / SK2 500 / GW 2 M
R-ISO / SK2 500 / GW 2 M
Switch the device under test off. Switch the device under test off.
Attention! Mains voltage will be ap-
plied to the DUT.
Attention! Mains voltage will be
applied to the DUT.
I-PE (L/N) / Diff 230 / GW 3,5 mA I-PE / Ersatz 230 / GW 3,5 mA I-PE / Ersatz 230 / GW 3,5 mA
Contact exposed conductive parts of the
DUT which are
not
connected to the
protective conductor (PE) with the probe
(socket 1/2).
Contact exposed conductive parts of
the DUT which are
not
connected to
the protective conductor (PE) with the
probe (socket 1/2).
Contact exposed conductive parts of the
DUT which are
not
connected to the
protective conductor (PE) with the probe
(socket 1/2)..
I-B (L/N) / Direkt 230 / GW 0,5 mA I-B (L/N) / Dirket 230 / GW 0,5 mA
R-ISO / SK2 500 / GW 2 M
R-ISO / SK2 500 / GW 2 M
Attention! Mains voltage will be ap-
plied to the DUT.
Attention! Mains voltage will be
applied to the DUT.
I-PE (N/L) / Diff 230 / GW 3,5 mA
Contact exposed conductive parts of the
DUT which are
not
connected to the
protective conductor (PE) with the probe
(socket 1/2).
I-B (N/L) / Direkt 230 / GW 0,5 mA I-B (N/L) /Direkt 230 / GW 0,5 mA I-B / Ersatz230 / GW 0,5 mA I-B / Ersatz230 / GW 0,5 mA
Switch the device under test off. Switch the device under test off. Switch the device under test off.