Manual
Table Of Contents
- 1 System requirements for local and client installation
- 2 Versions of IZYTRONIQ
- 3 Downloading BUSINESS and CLOUD Variants
- 4 Initial installation of BUSINESS Starter / Advanced / Professional / Premium
- 5 Initial installation of the ENTERPRISE Variant
- 6 Licensing
- 7 Update
- 8 Uninstallation
- 9 Login / Logout
- 10 Basics of operation
- 11 Home screen
- 12 Main modules
- 12.1 Module for portable objects
- 12.2 Module for stationary objects
- 12.3 Test device management
- 12.4 User management
- 12.5 Recycle bin
- 12.6 Settings
- 12.7 Synchronization (ENTERPRISE Ultimate only)
- 12.8 Help
- 13 Lists
- 14 Print
- 15 Document management
- 16 PUSH/PRINT
- 17 Sequence editor
- 18 Automatic process control for a test – remote function
- 19 Working in multi-user mode (floating license)
- 20 Data replication using the server
- 21 Editing report templates
- 22 SECUTEST/SECULIFE ST – first steps
- 23 PROFITEST – first steps
- 24 METRAHIT – first steps
- 25 NEXONIQ
- 25.1 License – Right of Utilization – Activation
- 25.2 Download
- 25.3 System Requirements of Local and Client Installation
- 25.4 Setup of User Interface
- 25.5 Reading out data from test instruments the formats of which are not compatible with IZYTRONIQ
- 25.6 Data import from ETC file
- 25.7 Importing the converted files into IZYTRONIQ
- 26 VIDEOS – Tutorial
- 26.1 “Sequence editor”Function “Input, change, list” – Portable Objects
- 26.2 Structure of the index cards – portable objects
- 26.3 File import – portable objects
- 26.4 Conflict manager – portable objects
- 26.5 Function “Input, change, list” – stationary objects
- 26.6 Structure of the index cards – stationary objects
- 26.7 Management and creation of test instruments
- 26.8 User management – BUSINESS Version except Premium variant
- 26.9 Global settings
- 26.10 Catalogs
- 26.11 Lists
- 26.12 Generation of test report
- 26.13 Push/Print
- 26.14 Sequence editor
- 26.15 Editing report templates
GMC-I Messtechnik GmbH 165
23 PROFITEST – first steps
The following devices are necessary to exchange data with IZYTRONIQ:
• PROFITEST INTRO < in preparation >
• PROFITEST MBASE+, PROFITEST MTECH+
• PROFITEST MPRO, PROFITEST MXTRA
• PROFITEST PRIME, PROFITEST PRIME AC
• SECULIFE IP
If the device is not yet registered in test device management, the user is asked whether it should be saved automatically. The test
device is now ready to share data with the IZYTRONIQ.
23.1 Creating a tree structure
To create test objects for the PROFITEST ..., navigate to the menu “STATIONARY OBJECTS” and select the function “INPUT/
CHANGE/LIST”. There you will find a screen consisting of three windows arranged one above the other. You can enlarge and reduce
the size of the windows by moving the upper, i.e. lower border that is marked by two short horizontal lines.
Upper window
– Left-hand side: E-TREE (electric tree)
– Right-hand side: Location tree
Central window: Detailed view of the master data for the test object
Lower window: List view of the objects
Electric tree
The stationary objects, machines or facilities are created here. Unlike with portable devices, IZYTRONIQ enables the creation of complex tree
structures. In this regard, PROFITEST and IZYTRONIQ have a broad variety of electrical sub-objects that can be freely selected and intro-
duced to an electric tree structure. In addition, a main object may possess another similar main object within this structure (machine
has a machine, or a facility has a facility). The following objects can be transferred with PROFITEST:
• Customer
• Facility
• Machine
• Distributor
• RCD
• RCM
• IMD
• Electric circuit
• Equipment
• Measurement point
• Equipotential bonding rail
• Equipotential bonding conductor
• Ground connector