Manual
Table Of Contents
- 1 System requirements for local and client installation
- 2 Versions of IZYTRONIQ
- 3 Downloading BUSINESS and CLOUD Variants
- 4 Initial installation of BUSINESS Starter / Advanced / Professional / Premium
- 5 Initial installation of the ENTERPRISE Variant
- 6 Licensing
- 7 Update
- 8 Uninstallation
- 9 Login / Logout
- 10 Basics of operation
- 11 Home screen
- 12 Main modules
- 12.1 Module for portable objects
- 12.2 Module for stationary objects
- 12.3 Test device management
- 12.4 User management
- 12.5 Recycle bin
- 12.6 Settings
- 12.7 Synchronization (ENTERPRISE Ultimate only)
- 12.8 Help
- 13 Lists
- 14 Print
- 15 Document management
- 16 PUSH/PRINT
- 17 Sequence editor
- 18 Automatic process control for a test – remote function
- 19 Working in multi-user mode (floating license)
- 20 Data replication using the server
- 21 Editing report templates
- 22 SECUTEST/SECULIFE ST – first steps
- 23 PROFITEST – first steps
- 24 METRAHIT – first steps
- 25 NEXONIQ
- 25.1 License – Right of Utilization – Activation
- 25.2 Download
- 25.3 System Requirements of Local and Client Installation
- 25.4 Setup of User Interface
- 25.5 Reading out data from test instruments the formats of which are not compatible with IZYTRONIQ
- 25.6 Data import from ETC file
- 25.7 Importing the converted files into IZYTRONIQ
- 26 VIDEOS – Tutorial
- 26.1 “Sequence editor”Function “Input, change, list” – Portable Objects
- 26.2 Structure of the index cards – portable objects
- 26.3 File import – portable objects
- 26.4 Conflict manager – portable objects
- 26.5 Function “Input, change, list” – stationary objects
- 26.6 Structure of the index cards – stationary objects
- 26.7 Management and creation of test instruments
- 26.8 User management – BUSINESS Version except Premium variant
- 26.9 Global settings
- 26.10 Catalogs
- 26.11 Lists
- 26.12 Generation of test report
- 26.13 Push/Print
- 26.14 Sequence editor
- 26.15 Editing report templates
162 GMC-I Messtechnik GmbH
22.2 Data export to the test device
The export function is used to transfer data to a test device or a file. The function is found under “EXPORT” in the menu “PORTA-
BLE OBJECTS” . Selecting this function opens the export assistant.
The export assistant asks whether the data should be exported to a connected test device or an XML or CSV file.
– TO THE TEST DEVICE: here you can choose between connected devices.
You can select OBJECTS and/or SEQUENCES.
– TO AN XML/CSV FILE: Touch the field “SAVE AS” to select the file in which you wish to save the data.
Selecting EXPORT starts the EXPORT FILTER.
Export filter
The export filter consists of two filter menus:
• EXPORT FILTER OBJECTS
• EXPORT SEQUENCES
When more than one filter menu is selected, the user switches between the views using the buttons “NEXT”, i.e. “BACK”. By
selecting the “EXPORT” button in the toolbar, the selected data and the corresponding customers and locations are transferred to
the connected test device. The current operation is shown during export. Users are shown a message once all data has been trans-
ferred successfully.
Take note !
Export deletes all data on the connected test device. You are therefore
shown a warning before export.