Manual
Table Of Contents
- 1 System requirements for local and client installation
- 2 Versions of IZYTRONIQ
- 3 Downloading BUSINESS and CLOUD Variants
- 4 Initial installation of BUSINESS Starter / Advanced / Professional / Premium
- 5 Initial installation of the ENTERPRISE Variant
- 6 Licensing
- 7 Update
- 8 Uninstallation
- 9 Login / Logout
- 10 Basics of operation
- 11 Home screen
- 12 Main modules
- 12.1 Module for portable objects
- 12.2 Module for stationary objects
- 12.3 Test device management
- 12.4 User management
- 12.5 Recycle bin
- 12.6 Settings
- 12.7 Synchronization (ENTERPRISE Ultimate only)
- 12.8 Help
- 13 Lists
- 14 Print
- 15 Document management
- 16 PUSH/PRINT
- 17 Sequence editor
- 18 Automatic process control for a test – remote function
- 19 Working in multi-user mode (floating license)
- 20 Data replication using the server
- 21 Editing report templates
- 22 SECUTEST/SECULIFE ST – first steps
- 23 PROFITEST – first steps
- 24 METRAHIT – first steps
- 25 NEXONIQ
- 25.1 License – Right of Utilization – Activation
- 25.2 Download
- 25.3 System Requirements of Local and Client Installation
- 25.4 Setup of User Interface
- 25.5 Reading out data from test instruments the formats of which are not compatible with IZYTRONIQ
- 25.6 Data import from ETC file
- 25.7 Importing the converted files into IZYTRONIQ
- 26 VIDEOS – Tutorial
- 26.1 “Sequence editor”Function “Input, change, list” – Portable Objects
- 26.2 Structure of the index cards – portable objects
- 26.3 File import – portable objects
- 26.4 Conflict manager – portable objects
- 26.5 Function “Input, change, list” – stationary objects
- 26.6 Structure of the index cards – stationary objects
- 26.7 Management and creation of test instruments
- 26.8 User management – BUSINESS Version except Premium variant
- 26.9 Global settings
- 26.10 Catalogs
- 26.11 Lists
- 26.12 Generation of test report
- 26.13 Push/Print
- 26.14 Sequence editor
- 26.15 Editing report templates
GMC-I Messtechnik GmbH 137
16 PUSH/PRINT
The Push/Print function is a convenient way of sending test results directly to the IZYTRONIQ database by pressing a button on the test
device. The measurement results are placed in the index card for tests under the selected test object and can be saved there.
Global test device support
The test results from test devices for any categories, i.e. standards, do not have to be stored and saved in the same categories (e.g.
stationary or portable). For instance, measured values for a protective conductor test, measured by the test device PROFITEST PRIME,
can be assigned to a portable test object.
16.1 Conducting a push/print test
A push/print tests can only be conducted with a test device that is push/print-capable. A push/print measurement cannot be selected
if the test device does not have this function.
In order to conduct a push/print test, the test device and IZYTRONIQ must be set to push/print mode. This is completed by creating a
new push/print test in the index card for tests, which is found in the detailed view for the selected test object.
As soon as the button “ADD” is selected, IZYTRONIQ all connected push/print-capable test devices are in the operating mode push/
print. This opens a two-part push/print window and the IZYTRONIQ is ready to receive. The master data for the push/print test is located
in the upper section, where the name of the test must be added. The measured data transfer is shown in the lower section once the
measurement is complete.
From then on, measurements can be sent to the selected test object in the IZYTRONIQ at the push of a button on any device that is in
push/print mode.