Operation Manual
GMC-I Messtechnik GmbH 19
Control Functions
4.1.2 Manual Measuring Range Selection
Auto-ranging can be deactivated and measuring ranges can be
selected manually in accordance with the following table by
pressing the MAN / AUTO button.
The desired measuring range can then be selected with the
or
scroll key.
The instrument is automatically returned to automatic range se-
lection when the MAN / AUTO key is pressed, the rotary switch is
activated or the instrument is switched off and back on again.
Overview: Auto-Ranging and Manual Range Selection
* Via manual measuring range selection only
Function Display
MAN / AUTO
Manual mode active:
utilized measuring range is fixed
MAN
or
Range switching sequence for:
V :
300 mV*
↔
3V
↔
30 V
↔
300 V
↔
600 V
Hz (V AC)
:300 Hz
↔
3 kHz
↔
30 kHz
↔
300 kHz
MHz:
300 Hz
↔
3 kHz
↔
30 kHz
↔
300 kHz
↔
1 MHz
Ω
:
300
Ω ↔
3 k
Ω ↔
30 k
Ω ↔
300 k
Ω ↔
3 M
Ω ↔
30 M
Ω
A :
300
μ
A
↔
3 mA
↔
30 mA
↔
300 mA
↔
3A
↔
10 A (16 A)
Hz (A AC):
300 Hz
↔
3 kHz
↔
30 kHz
F :
3 nF
↔
30 nF
↔
300 nF
↔
3
μ
F
↔
30
μ
F
↔
300
μ
F
↔
↔
3
mF
MAN
MAN / AUTO
Return to automatic measuring range selection —