Operation Manual
14 GMC-I Messtechnik GmbH
Operating Overview – Connections, Keys, Rotary Switch, Symbols
Symbols used for Rotary Switch positions
* POL / UISO CAP:1
Switch
FUNC
Display Measuring Function
V~ 0/4 V~ AC TRMS Alternating voltage, AC TRMS, full bandwidth
Hz (V) 1 Hz ~ AC Voltage frequency, full bandwidth
V~ 2 V Fil ~ AC TRMS Alternating voltage, AC TRMS, with low pass filter (200 Hz)
Hz (V)
3 Hz Fil ~ AC Voltage frequency, with low pass filter (200 Hz)
V 0/2 V DC Direct voltage
V 1 V DC AC TRMS Pulsating voltage, TRMS ( )
R
SL
0/3 RPE Ω Loop impedance measurement with acoustic signal where I is constant
1 Ω Continuity test with acoustic signal
2
V DC Diode voltage where I is constant
Ω
0/2 Ω (DC) resistance
Temp. RT D 1 °C Pt 100/1000 Temperature with Pt 100 / Pt 1000 resistance thermometer
0/2 nF Capacitance
m (km) 1 m (km) Cable length (via capacitive linear electric constant)
a-b, a-E, b-E
0/2 V Extraneous voltage test
M
Ω
ISO
@10V/100V
1 ISO 100 V / kΩ / MΩ Insulation resistance measurement:
CAP
* nF Interference-immune capacitance measurement in selector switch positions (a-b)(a-E)(b-E)
A 0/2 A DC Direct current value
A 1 A DC AC TRMS Pulsating current amperage, AC DC TRMS
A~ 0/2 A~ AC TRMS Alternating current amperage, AC TRMS
Hz (A) 1 Hz ~ AC Current frequency
0/2 A DC DC amperage with AC DC clip-on current sensor, 1 V:1/10/100/1000 A
1 A DC AC TRMS Pulsating current amperage, TRMS, with AC DC clip-on current sensor, see above
0/2 A~ AC TRMS Alternating current amperage, TRMS, with clip-on current sensor, see above
Hz ( ) 1 Hz ~ AC Current frequency with clip-on current sensor, see above
200 Hz
200 Hz
V
ACDC
V
AC
2
V
DC
2
+=
A
A
A
A