Datasheet

GMC-I Messtechnik GmbH 3
METRAHITT-COM PLUS
Cable Multimeter for Measurements
in Symmetrical Copper Cable Networks
Characteristic Values
1)
15 ... 45 ... 65 Hz ... 10 (5) kHz sine. For influence see page 4.
2)
At 0to + 40 C
3)
Display of up to max. 5.1 V, “OL” in excess of 5.1 V.
4)
Applies to measurements at film capacitors and with battery operation
5)
Lowest measurable frequency for sinusoidal measuring signals symmetrical to the
zero point
6)
Overload capacity of the voltage measurement input:
power limiting: frequency x voltage max. 6 x 10
6
V x Hz: e.g. max. 600 V 1 kHz
7)
Overload capacity of the current measurement input:
See current measuring ranges for maximum current values.
8)
Input sensitivity, sinusoidal signal, 10% to 100% of the voltage or current
measuring range; limitation: up to 30% of the range at up to 100 kHz in the
mV measuring range, 50% of the range at up to 300 kHz, 30% of the range in the
1 A measuring range.
The voltage measuring ranges with max. 30 kHz apply in the A measuring range.
9)
Plus sensor deviation
10)
With ZERO function active
11)
With short circuited terminal tips
Exception: residual value of 1 to 10 digits,
in the mV/A range,
1 to 35 digits as zero point due to the TRMS converter
Key: R = measuring range, d = digit(s), rdg. = measured value
(reading)
Meas.
Func-
tion
(input)
Measuring Range
Resolution at
Upper Range
Limit
Input impedance
Intrinsic Uncertainty under Reference Conditions
Overload Capac-
ity
2)
(... % rdg. + ... d) (... % rdg. + ... d) (... % rdg. + ... d)
~ /
~
1), 11)
1), 11)
Value Time
V
(a)
300.0 mV 100 V9M 9M // < 50 pF 0.5 + 3
10)
1.5 + 3 (> 300 d) 1.5 + 3 (> 300 d)
600 V
DC
AC
RMS
Sine
6)
Cont.
3.000 V 1 mV 9 M 9M // < 50 pF 0.5 + 1
1.5 + 3 (> 30 d) 1.5 + 3 (> 100 d)
30.00 V 10 mV 9 M 9M // < 50 pF 0.5 + 1
300.0 V 100 mV 9 M 9M // < 50 pF 0.5 + 1
600 V 1 V 9 M 9M // < 50 pF 0.5 + 1
Voltage drop at approx. range limit
~
1), 11)
1), 11)
A
(E)
300.0 A 100 nA 18 mV 18 mV 0.5 + 5 1.5 + 5 (> 100 d) 1.5 + 5 (> 100 d)
0.3 A Cont.
3.000 mA 1 A 160 mV 160 mV
0.5 + 3
1.5 + 5 (> 30 d) 1.5 + 5 (> 100 d)
30.00 mA 10 A 32 mV 32 mV
300.0 mA 100 A 320 mV 320 mV
1.000 A 1 mA 600 mV 600 mV 0.5 + 5 1.6 A 5 min.
Factor: 1:1/10/100/1000
Input Input impedance
~
1), 11)
1), 11)
A
(a)
0.3/3/30/300 A 300 mV
Voltage measurement input approx. 9 M
( V socket)
0.5 + 3
1.5 + 3 (> 300 d) 1.5 + 3 (> 300 d)
Measurement input
3/30/300/3k A 3 V 1.5 + 3 (> 30 d) 1.5 + 3 (> 100 d)
600 V
TRMS
Max. 10 s
30/300/3k/30k A
30 V Plus clip-on current sensor error
Open-circuit volt-
age
Meas. current at
range limit
(... % rdg. + ... d)
(a)
300.0 100 m < 1.4 V Approx. 250 A
0.5 + 3 with ZERO function active
600 V
DC
AC
RMS
Sine
Max. 10 s
3.000 k 1 < 1.4 V Approx. 160 A 0.5 + 1
30.00 k 10 < 1.4 V Approx. 28 A 0.5 + 1
300.0 k 100 < 1.4 V Approx. 2.9 A 0.5 + 1
3.000 M 1k < 1.4 V Approx. 0.31 A 0.5 + 1
30.00 M 10 k < 1.4 V Approx. 33 nA 2.0 + 5
R
SL
300.0 100 m Approx. 13 V
Approx. 2 mA const.
3 + 5
3.000 k 1 Approx. 13 V 3 + 5
300.0 100 m Approx. 3 V
Approx. 1 mA const.
3 + 5
5.1 V
3)
1mV Approx. 13 V 2 + 5
Discharge resistance
U
0 max
(... % rdg. + ... d)
F
(a)
30.00 nF 10 pF 10 M 0.7 V 1 + 6
4)
with ZERO function active
600 V
DC
AC
RMS
Sine
Max. 10 s
300.0 nF 100 pF 1 M 0.7 V 1 + 6
4)
3.000 F 1 nF 100 k 0.7 V 1 + 6
4)
30.00 F10nF 12k 0.7 V 1 + 6
4)
300.0 F 100 nF 3 k 0.7 V 5 + 6
4)
f
min
5)
(... % rdg. + ... d)
Hz (V)/
Hz (A)
300.0 Hz 0.1 Hz
1Hz
0.5 + 1
8)
Hz (V)
6)
:
Hz (A )
6)
:
600 V
Hz (A):
7)
Max. 10 s
3.000 kHz 1 Hz
30.00 kHz 10 Hz 10 Hz
Hz (V)
300.0 kHz 100 Hz 100 Hz
(... % rdg. + ... d)
9)
C
Pt100
200.0 ...
+200.0 C
0.1 C
2 K + 5
600 V
DC/AC
RMS
Sine
Max. 10 s
+200.0 ...
+850.0 C
1 + 5
Pt1000
150.0 ...
+200.0 C
2 K + 5
+200.0 ...
+850.0 C
1 + 5