Datasheet

GMC-I Messtechnik GmbH
3
METRAHITENERGY
TRMS SYSTEM Multimeter
Battery Charging Status – Power Saving Circuit
The battery charging status is indicated by means of four sym-
bols.
The device is switched off automatically if the measured value
remains unchanged for a period of between 10 and 59 minutes
(adjustable), and if none of the controls are activated during this
time (automatic shutdown is deactivated for power and energy
measurement as well as for power quality analysis).
Automatic shutdown can be disabled by switching the instrument
to continuous operation.
The standby mode for the infrared interface can be deactivated.
Protective Cover for Harsh Conditions
The instrument is protected against damage in the event of
impacts or dropping by means of a soft rubber cover with tilt stand
and test probe holder. The rubber material also assures that the
instrument does not wander if it is set up on a vibrating surface.
Infrared Data Interface
The device can be remote configured, and momentary and saved
measurement data can be read out via the bidirectional infrared
interface. The USB X-TRA interface adapter and METRAwin 10
software are required to this end (see accessories). An interface
protocol and device drivers for LabVIEW® (National Instru-
ments™) are available upon request.
DKD Calibration Certificate
Each multimeter is individually adjusted, subjected to final inspec-
tion and calibrated. Adherence to the specification is confirmed
by means of the included DKD calibration certificate, which is
valid worldwide (recognized by EA and ILAC). After the specified
calibration interval has elapsed (recommended interval: 1 to 3
years), the multimeters can be recalibrated at any time in our own
DKD calibration laboratory.
Applicable Regulations and Standards
Scope of Delivery
1multimeter
1 KS29 (3 safety measurement cables with 4 mm test probes,
1000 V CAT III, 600 V CAT IV)
2 batteries, 1.5 V, type AA
1 condensed operating instructions, English/German
1 CD ROM with operating instructions in English and German
1 DKD calibration certificate
1 rubber holster
Extended, Voluntary Manufacturer’s Guarantee
36 months for materials and workmanship
1 to 3 years for calibration (depending upon application)
Functions Overview
1
16 Mbit = 2048 kByte = up to 300,000 measured values,
sampling rate adjustable from 0.5 second to 9 hours
IEC/EN 61010, part
1:2001/VDE 0411-1:2002
Safety requirements for electrical equipment for
measurement, control and laboratory use
DIN EN 61326-1
VDE 0843-20-1
Electrical equipment for measurement, control and laboratory
use – EMC requirements – Part 1: General requirements
DIN EN 60529
DIN VDE 0470, part 1
Test instruments and test procedures – Degrees of protection
provided by enclosures (IP code)
Function
Power measurement
W (Var, VA, PF)
Energy measurement
Wh (varh, VAh)
Energy recording
DC / AC events
Power disturbance recording PQ
Harmonic Analysis
V, A
Voltage (Ri 17 M)
V
DC
Voltage (Ri 9 M)
V
AC
TRMS
Voltage (Ri 9 ... 17 M)
V
AC+DC
TRMS
Crest factor (1 CF 11)
Frequency in Hz with V
AC
... 300 kHz
Low-pass filter 1 kHz with V
AC
Bandwidth for V
AC+DC
or V
AC
100 kHz
Pulse frequency in MHz at 5V
TTL
1 Hz...1 MHz
Duty cycle as %
2.0% ... 98%
Voltage level measurement in dB
Resistance
Conductivity
nS
Low resistance measurement
with I
CONST
= 3 mA
R
SL
Continuity test
with I
CONST
= 1 mA
Diode test
with I
CONST
= 1 mA
Temperature measurement C/F with T
C
Type K
Temp. measurement C/F R
TD
Pt100/Pt1000
Capacitance measurement in F
Cable length in m
Current A
DC
A
AC
TRMS
A
AC+DC
TRMS
Bandwidth for A
AC+DC
or A
AC
10 kHz
Frequency in Hz for A
AC
... 60 kHz
Current clamp measurement with adjustable transformation
ratio
mV / A
mA / A
Relative value measurement (reference value measurement)
REL
Zero point
Data logger function
1
(memory) 16 MBit
Min / Max / data hold
IR interface (38.4 kBd)
Power pack socket
Rubber holster
Fuse 10 A / 1000 V
Protection
3
IP 52
Measuring category 600 V CAT III
300 V CAT IV
Calibration
DKD