Datasheet

GMC-I Gossen-Metrawatt GmbH 3
METRAHITX-TRAOUTDOORTECHPROBASE
TRMS Digital Multimeters
Characteristic Values
1)
Values of less than 200 digits are suppressed in the mV range
2)
At 0 ° ... + 40 °C
3)
Displays up to max. 5.1 V, “OL” in excess of 5.1 V
4)
Applies to measurements at film capacitors
5)
Lowest measurable frequency for sinusoidal measuring signals symmetrical to the zero point
6)
Overload capacity of the voltage measurement input:
power limiting: frequency x voltage max. 3 x 10
6
V x Hz for U > 100 V
7)
Overload capacity of the current measurement input:
See current measuring ranges for maximum current values
8)
Input sensitivity, sinusoidal signal, 10% to 100% of the measuring range
9)
Plus sensor deviation
10)
Residual value deviates within 1 ... 30 d from the zero point due to TRMS converter
when probe tips are short-circuited. See frequency influence on page 4
11)
Off-time > 30 min. and T
A
40 °C
Key:
R = measuring range, d= digit(s), rdg. = measured value (reading)
Meas.
Function
Measuring Range
Resolution at Upper
Range Limit
Input Impedance
Intrinsic Errorunder Reference Conditions
Overload Capacity
2)
±(... % rdg. + ... d) ±(... % rdg. + ... d) ±(... % rdg. + ... d)
11,999 1199
~ /
~
10)
10)
Value Time
V
100 mV 10 μV 9MΩ≥ 9MΩ // < 50 pF 0.09 + 5 with ZERO 1 + 30 (> 300 d)
1)
1 + 30 (> 300 d)
1)
1000 V
DC
AC
RMS
sine
Continu-
ous
1 V 100 μV 9MΩ≥ 9MΩ // < 50 pF 0.05 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
10 V 1 mV 9MΩ≥ 9MΩ // < 50 pF 0.05 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
100 V 10 mV 9MΩ≥ 9MΩ // < 50 pF 0.05 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
1000 V 100 mV 9MΩ≥ 9MΩ // < 50 pF 0.09 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
Voltage drop, approx. at upper range limit ~
10)
10)
A
X-
TRA
O
UTDOOR
PRO
100 μA 10 nA 12 mV 12 mV 0.5 + 5 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
0,2 A dauernd
1 mA 100 nA 120 mV 120 mV 0.5 + 3 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
10 mA 1 μA 16 mV 16 mV 0.5 + 3 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
100 mA 10 μA 160 mV 160 mV 0.5 + 3 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
1 A 100 μA 40 mV 40 mV 0.9 + 10 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
10 A: 5 min
11)
16 A: 30 s
11)
10 A 1 mA 600 mV 600 mV 0.9 + 10 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
A
T
ECH
10 mA 1 μA 16 mV 16 mV 0.1 + 5 1 + 10 (> 200 d) 1.5 + 30 (> 200 d)
0,2 A dauernd
100 mA 10 μA 160 mV 160 mV 0.1 + 5 1 + 10 (> 200 d) 1.5 + 30 (> 200 d)
1 A 100 μA 40 mV 40 mV 0.9 + 10 1 + 10 (> 200 d) 1.5 + 30 (> 200 d)
10 A: 5 min
11)
16 A: 30 s
11)
10 A 1 mA 600 mV 600 mV 0.9 + 10 1 + 10 (> 200 d) 1.5 + 30 (> 200 d)
Factor: 1:1/10/100/1000
Input Input impedance
A
T
ECH
0,1/1/10/100 A 100 mA
Current measuring input
(A socket)
Specification see current ranges A (T
ECH)
Measuring input
1/10/100/1000 A 1 A
0,2 A continuous
10 A: 5 min
10/100 /1 00 0 / 10000 A
10 A plus clip-on current sensor error
A
T
ECH
BASE
0.1/1/10/100 A 100 mV
Voltage measurement input
T
ECH: (V socket) Ri =1 MΩ/9 MΩ
B
ASE: ( V socket) Ri ~1 MΩ
±(0.5% rdg. + 10 d)
±(1% rdg. + 30 d)
> 300 d
±(1% rdg. + 30 d)
> 300 d
Measurement input
1/10/100/1000 A 1 V
1000 V RMS Max. 10 s
10/100 /1 00 0 / 10000 A
10 V Plus clip-on current sensor error
Open-circuit voltage
Meas. curr. @ range limit
±(... % rdg. + ... d)
Ω
100 Ω 10 mΩ < 1.4 V Approx. 300 μA0.2 + 5
with active ZERO function
1000 V
DC
AC
RMS
sine
Max. 10 s
1kΩ 100 mΩ < 1.4 V Approx. 250 μA0.2 + 5
10 kΩ 1 Ω < 1.4 V Approx. 100 μA0.2 + 5
100 kΩ 10 Ω < 1.4 V Approx. 12 μA0.2 + 5
1MΩ 100 Ω < 1.4 V Approx. 1.2 μA0.2 + 5
10 MΩ 1kΩ < 1.4 V Approx. 125 nA 0.5 + 10
40 MΩ 10 kΩ < 1.4 V Approx. 20 nA 2.0 + 10
100 Ω —0.1Ω Approx. 8 V Approx. 1 mA const. 1 + 5
5,1 V
3)
1 mV Approx. 8 V Approx. 1 mA const. 0.5 + 3
X
-
TRA
/ O
UTDOOR
PRO
TECH
Discharge resist. U
0 max
±(... % rdg. + ... d)
F
X-
TRA
O
UTDOOR
TECH
10 nF 10 pF 10 MΩ 0.7 V 1 + 6
4)
with ZERO function active
1000 V
DC
AC
RMS
sine
Max. 10 s
100 nF 100 pF 1 MΩ 0.7 V 1 + 6
4)
1 μF 1 nF 100 kΩ 0.7 V 1 + 6
4)
10 μF10nF12kΩ 0.7 V 1 + 6
4)
100 μF 100 nF 3 kΩ 0.7 V 5 + 6
4)
1000 μF1μF3kΩ 0.7 V 5 + 6
4)
f
min
5)
±(... % rdg. + ... d)
Hz (V)
Hz (A)
Hz (A )
100.00 Hz 0.01 Hz
1Hz
0.05 + 3
8)
Hz (V)
6)
:
Hz (A )
6)
:
1000 V
Hz (A):
7)
Max. 10 s
1.0000 kHz 0.1 Hz
10.000 kHz 1 Hz
Hz (V)
100.00 kHz 10 Hz 10 Hz
Hz (A)
30.00 kHz 10 Hz 10 Hz
MHz
X-TRA
O
UTDOOR
100 Hz ... 1 MHz
0,01
...100 Hz
1 ... 100 Hz 0.05 + 3 > 2 V ... 5 V
1000 V Max. 10 s
%
X-
TRA
O
UTDOOR
2.0 ... 98 % 0.01% 100 Hz ... 1 kHz 1 Hz 0.1 R > 2 V ... 5 V
5.0 ... 95 % 0.01% ... 10 kHz 1 Hz 0.1 R per kHz > 2 V ... 5 V
10 .... 90 % 0.01% ... 100 kHz 1 Hz 0.1 R per kHz > 2 V ... 5 V
±(... % rdg. + ... d)
°C/°F
Pt100
OUTD.
200.0 ...
+850.0 °C
0.1 °C
0.3 + 15
9)
1000 V
DC/AC
RMS
Sine
Max. 10 s
Pt1000
OUTD.
150.0 ...
+850.0 °C
0.3 + 15
9)
K
(NiCr-Ni)
250.0 ...
+1372.0 °C
1% + 5 K
9)