User Manual

GOSSEN METRAWATT GMBH 19
5 Technical Characteristics
Voltage Measuring Ranges
1)
0dB 0.775 V in the range of 1.5 V ; 0 dB 1 mW at 600
Input resistance in relation to voltage for : 20.0 k/V
for : 4.0 k/V
METRA HIT 1A: Current Measuring Ranges
Voltage Output
1
)
Internal Resistance approx.
0.15 V 3.15 k
0.50 V 10.00 k
1.50 V –15 ... + 6 dB 31.50 k 6.50 k
5.00 V 5 ... + 16 dB 100.00 k 20.00 k
15.00 V + 5 ... + 26 dB 315.00 k 65.00 k
50.00 V +15 ... + 36 dB 1.00 M 200.00 k
150.00 V +25 ... + 46 dB 3.15 M 650.00 k
500.00 V +35 ... + 56 dB 10.00 M 2.00 M
Current
Voltage Drop approx.
50.00 µA 0.158 V
0.50 mA 1.15 V 1.00 V
5.00 mA 1.25 V 1.25 V
50.00 mA 1.25 V 1.25 V
500.00 mA 1.85 V 1.85 V
5000.00 mA 1.73 V 1.73 V