Datasheet
3-349-304-03
2/7.04
GOSSEN METRAWATT GMBH
METRA HIT 1A and METRA HIT 2A
Analog Multimeters
500 V CAT II
IEC/EN 61010-1, Second Edition
5 Ampere 15 Ampere / Class 2.5
Broad Range of Applications
A large number of measuring ranges allows for universal use of
the instruments, for example in electronics, digital technology and
a wide variety of general electrical applications.
Safety Features
The connector jacks and plugs included with the measurement
cables which are available as accessories are protected against
inadvertent contact.
Measuring Range Selector Switch
All measuring ranges are selected with a rotary switch.
Rugged Mechanical Design
The rugged plastic housing and the spring loaded bearing jewels
in the moving-coil mechanism protect the instrument from
damage due to mechanical stressing. Especially effective
protection is provided by the protective rubber cover and the
ever-ready case, both of which are available as accessories.
Applicable Regulations and Standards
Characteristic Values
Voltage Measuring Ranges
1)
0 dB 0.775 V in the 1.5 V range, 0 dB 1 mW to 600 Ω
Voltage related input resistance: for : 20.0 kΩ/V
for : 4.0 kΩ/V
METRA HIT 1A: Current Measuring Ranges
IEC/EN 61010-1:2001/
VDE 0411-1:2002
Safety requirements for electrical equipment for
measurement, control and laboratory use
EN 60529
VDE 0470, part 1
Test instruments and test procedures,
degrees of protection provided by enclosures (IP code)
DIN EN 61326
VDE 0843, part 20
Electrical equipment for control technology and
laboratory use – EMC requirements
Voltage Output
1)
Internal Resistance, Approx.
0.15 V — 3.15 kΩ —
0.50 V — 10.00 kΩ —
1.50 V -15 ... + 6 dB 31.50 kΩ 6.50 kΩ
5.00 V - 5 ... + 16 dB 100.00 kΩ 20.00 kΩ
15.00 V + 5 ... + 26 dB 315.00 kΩ 65.00 kΩ
50.00 V +15 ... + 36 dB 1.00 MΩ 200.00 kΩ
150.00 V +25 ... + 46 dB 3.15 MΩ 650.00 kΩ
500.00 V +35 ... + 56 dB 10.00 MΩ 2.00 MΩ
Current
Voltage Drop, Approx.
50.00 µA 0.158 V —
0.50 mA 1.15 V 1.00 V
5.00 mA 1.25 V 1.25 V
50.00 mA 1.25 V 1.25 V
500.00 mA 1.85 V 1.85 V
5000.00 mA 1.73 V 1.73 V
• Voltage measurement:
0...0.15, 0...0.5 V=, 0 ...1.5, 5, 15, 50, 150, 500 V=/~
• Input resistance: 20 kΩ/V=, 4 kΩ/V~
• Current measurement: 0 ... 50 µA=, 0 ... 0.5, 5, 50, 500 mA,
5 A=/~
• Extended current measurement, METRA HIT 2A: ... 15 A=/~
• Resistance measurement: 1 Ω ... 1 MΩ (4 ranges)
• Capacitance: 200 mF ... 2 µF (4 ranges)
• Level: -15 ... +56 dB (6 ranges)