User manual

GMC-I Messtechnik GmbH 13
Reference Conditions
Ambient temperature
+23 °C ±2K
Relative humidity 40 ... 60%
Line voltage
MINITEST Master / Pro / Base: 230 V ±1%
MINITEST 3P Master: 230 V/400 V ±1%
Measured quantity
frequency 50 Hz ±0.2%
Measured quantity
waveshape Sine (deviation
between RMS and
rectified value:
±0.5%)
Ambient Conditions
Operating temp. 0 to + 40 °C
Storage temp. range 20 to +70 °C
Humidity Max.75%, no con-
densation allowed
Elevation to 2000 m
Power Supply
Line voltage
MINITEST Master / Pro / Base
:
230 V 50 Hz
MINITEST 3P Master: 230V/400V50Hz
Throughput rating
MINITEST Master / Pro / Base
:
max. 3700 VA
MINITEST 3P Master: max. 38.4 kVA
depending upon load at the mains outlet
Electrical Safety
Safety class I
Nominal line voltage 230 V
Tes t volt age
Mains + PE (mains) to
test outlet,
probe socket PE/I
C
or
R
ISO
: 1.5 kV
Mains to PE (mains):
3 kV
Measuring category 300 V CAT II
Contamination degree
2
Fuse FF0,315H1000V
or FF0,315H500V
or FF0,315H250V
MINITEST 3P Master
only:
3 x C16A
Residual current
protective device
(
MINITEST Master / Pro
)
30 mA with
undervoltage trigger
and inhibiting of
automatic restart
Display and Indicating Devices
LCD (not for MINITEST Base)
Dot matrix display, two lines of 20 charac-
ters each
LEDs
9 LEDs for indicating compliance with or
violation of limit values:
1 red, 7 yellow and 1 green
Mechanical Design
Dimensions/weight
MINITEST Master / Pro / Base:
W x H x D: 200 mm x 1mm x 77 mm
(without integrated outlets, grommets and
rotary switch)
Weight approx. 1.5 kg
MINITEST 3P Master
W x H x D: 350 mm x 160 mm x 125 mm
(without surface-type outlets, grommets, cir-
cuit breaker and rotary switch)
(overall dimensions without cables)
Weight approx. 3.3 kg
Protection housing IP 44,
terminals IP 20
Table excerpt regarding significance of the
IP code
s
Electromagnetic Compatibility (EMC)
Interference emission EN 61326-1:2006
class B
Interference immunity EN 61326-1:2006
IP XY
(1
st
digit X)
Protection
against foreign
object entry
IP XY
(2
nd
digit Y)
Protection
against the
penetration of
water
2 12.5 mm dia.
0 not protected
4 1.0 mm dia.
4 splashing water