User manual
10 GMC-I Messtechnik GmbH
6 Report Functions
Depending on the selected operating mode,
the measured values and the result of each
test can be transmitted to a PC via USB port
for onward processing or stored to the inter-
nal device memory. The transmission or
storage process of measured values is indi-
cated by all LEDs lighting briefly up from
right to left.
Selection of Operating Mode
The corresponding PC analysis software
programs have to be installed and started for
the three different operating modes in order
to receive data, see table above.
Press key „S“ (6) when switching on the
instrument to set the requested operating
mode. The following operating modes are
shown in subsequent order:
• „Transmission mode“, siehe chapter 6.1
• „Permanent transmission“, see chapter 6.2
• „Memory mode“, see chapter 6.3
The operating mode which is indicated when
releasing key „S“ (6) is selected. This setting
remains active even after switching off the
instrument.
6.1 Transmission Mode
To transmit the current measured value, key
„S“ must be pressed in operating mode
„Transmission mode“.
6.2 Permanent Transmission
If operating mode „Permanent transmission“
is activated, each measured value is trans-
mitted via the USB port.
6.3
Memory Mode
In the test instruments MINITEST Master or
MINITEST 3P Master a maximum of 2,047
DUTs with 10 measured values per DUT can
be stored. If an attempt is made to store
more than 10 measured values for one DUT,
the additional values are ignored and the red
LED lights up briefly.
6.3.1 Activate Memory Menu
After selecting memory mode (see above) you
have to set the rotary switch to position
Gerä-
teselbsttest/Speichermenü (
Self-test/Mem-
ory Menu)
. Activate the memory menu by
pressing key „S“ (6). The following is shown on
the LCD:
** MEMORY MENU ** SELECTION -> SWITCH.
You may now select the requested memory
function via the rotary switch.
6.3.2 Selecting Memory Function
➭ Key NUM – > Menu DUT NUM –
The number of the current memory location
is reduced by one each time key „S“ (6) is
pressed. The lowest possible value is „1“.
The letter „D“ in front of the number signifies
that data are already available for this mem-
ory location.
➭ Key NUM + > Menu DUT NUM+
The number of the current memory location
is increased by one each time key „S“ (6) is
pressed. The highest possible value is
„2,047“, i.e. a maximum of 2,047 DUTs can
be tested. The letter „D“ in front of the num-
ber signifies that data are already available
for this memory location.
Operating mode selected at the test
instrument
MINITEST 3P Master
MINITEST Master
MINITEST Pro
Transmission mode
(Transmission of individual measured values)
✘
✘✘
Permanent transmission
(Continuous transmission of measured values)
✘✘✘
Memory mode
(Internal measured value memory)
✘✘—