Datasheet
PROFITEST MTECH+, MPRO, MXTRA, SECULIFE IP
DIN VDE 0100/IEC 60364-6 Testers
2 GMC-I Messtechnik GmbH
Display with Selectable Language
The LCD panel consists of a backlit dot matrix at which menus,
setting options, measurement results, tables, instructions and
error messages, as well schematic diagrams appear.
The display can be set to the desired language depending on the
country in which the test instrument is used:
D, GB, I, F, E, P, NL, S, N, FIN, CZ or PL
Operation
Device functions are selected directly with the help of a rotary
selector knob. Softkeys allow for convenient selection of sub-
functions and parameter settings. Unavailable functions and
parameters are automatically prevented from appearing at the
display.
The start and RCD tripping functions included directly on the
instrument are identical to the functions of the two keys located
on the test plug, allowing for easy measurement at difficult to
access locations.
Schematic diagrams, measuring ranges and help texts cab be
displayed for all basic functions and sub-functions.
Phase Tester
Protective conductor potential is tested after starting a test
sequence and touching the contact surface for finger contact.
The PE symbol appears at the display if a potential difference of
more than 25 V is detected between the contact surface and the
protective contact at the mains plug.
Error Indication
• The instrument automatically detects instrument-to-system con-
nection errors, which are indicated in a connection pictograph.
• Errors within the electrical system (no mains or phase voltage,
tripped RCD) are indicated at 3 LEDs and by means of pop-
up windows at the tilting LCD panel.
Battery Monitoring and Self-Test
Battery monitoring is conducted while the instrument is subjected
to an electrical load. Results are displayed both numerically and
with a symbol. Test images can be called up one after the other,
and LEDs can be tested during the self-test. The instrument is
shut down automatically when the rechargeable batteries are dis-
charged. A microprocessor controlled charging circuit is used to
assure safe charging of rechargeable NiMH or NiCd batteries.
Data Entry at the RS 232 Port
Data can be read in via a barcode or RFID scanner connected to
the RS 232 port, and comments can be entered with the help of
the softkeys.
IZYTRONIQ User Software for PC
IZYTRONIQ is a test software developed from scratch. It enables
the user to visualize and manage the entire testing procedure for
all our test instruments and to document it in an audit-proof man-
ner. For the first time, it is thus possible to combine the test and
measurement data from a great variety of test instruments and
multimeters in one test and generate one report report thereof.
The intuitive user guidance and modern design provide for quick
access to all functions.
The software is available in different sizes and versions for trades,
industry and vocational training purposes.
Overview of Features Included with PROFITEST MASTER &
SECULIFE IP Device Variants
1
So-called live measurement is only advisable if there is no bias current within
the system. Only suitable for motor circuit breaker with low nominal current.
2
Currently available languages: D, GB, I, F, E, P, NL, S, N, FIN, CZ, PL
PROFITEST ...
(Article Number)
MPRO
(M535C)
M
TECH+
(M535B)
M
XTRA
(M535D)
SECULIFE IP
(M535E)
Testing of residual current devices (RCDs)
U
B
measurement without tripping RCD
3 33
✓
Tripping time measurement
3 33
✓
Measurement of tripping current I
F
3 33
✓
Selective, SRCDs, PRCDs, type G/R
3 33
✓
AC/DC sensitive RCDs, type B, B+ —
33
✓
Testing of IMD s — —
3
✓
Testing of RCMs — —
3
—
Testing for N-PE reversal
3 33
✓
Measurement of loop impedance Z
L-PE
/ Z
L-N
Fuse table for systems without RCDs
3 33
✓
Without tripping the RCD, fuse table —
33
✓
With 15 mA test current
1)
without tripping the RCD
3 33
✓
Earthing resistance R
E
(mains operation)
I-U measuring method (2/3-wire measuring method
via measuring adapter: 2-wire/2-wire + probe)
3 33
✓
Earthing resistance R
E
(battery operation)
3 or 4-wire measurement via PRO-RE adapter
3
—
3
—
Soil resistivity
ρ
E
(battery operation)
(4-wire measurement via PRO-RE adapter)
3
—
3
—
Selective earthing resistance R
E
(mains opera-
tion)
with 2-pole adapter, probe, earth electrode and
current clamp sensor (3-wire measuring method)
3 33
✓
Selective earthing resistance R
E
(battery operation)
with probe, earth electrode and current clamp
sensor (4-wire measuring method via PRO-RE
adapter and current clamp sensor)
3
—
3
—
Earth loop resistance R
ELOOP
(battery operation)
with 2 clamps (current clamp sensor direct
and current clamp transformer via PRO-RE/2 adapter)
3
—
3
—
Measurement of equipotential bonding R
LO
,
automatic polarity reversal
3 33
✓
Insulation resistance R
ISO
,
variable or rising test voltage (ramp)
3 33
✓
Voltage U
L-N
/ U
L-PE
/ U
N-PE
/ f
3 33
✓
Special measurements
Leakage current (with clamp) I
L
, I
AMP
3 33
✓
Phase sequence
3 33
✓
Earth leakage resistance R
E(ISO)
3 33
✓
Voltage drop (ΔU)
3 33
✓
Standing-surface insulation Z
ST
3 33
✓
Meter start-up (kWh-Test)
3 33
—
Leakage current with PRO-AB adapter (IL)
— —
3
✓
Residual voltage test (Ures)
— —
3
—
Intelligent ramp (ta + ΔI)
— —
3
—
Electric vehicles at charging stations (IEC 61851)
—
33
—
Report generation of fault simulations on
PRCDs with PROFITEST PRCD adapter
— —
✓
—
Features
Selectable user interface language
2
3 33
✓
Memory (database for up to 50,000 objects)
3 33
✓
Automatic test sequence function
3 33
✓
RS 232 port for RFID/barcode scanner
3 33
✓
USB port for data transmission
3 33
✓
Interface for Bluetooth® —
33
✓
IZYTRONIQ BUSINESS Starter
database and report software for PC
3 33
✓
Measuring category: CAT III 600 V / CAT IV 300 V
3 33
✓
DAkkS calibration
3 33
✓