- 11 Measuring Voltage and Frequency
- 12 Testing RCDs
- 12.1 Measuring Touch Voltage (with reference to nominal residual current) with ⅓ Nominal Residual Current and Tripping Test with Nominal Residual Current
- 12.2 Special Tests for Systems and RCDs
- 12.2.1 Testing Systems and RCCBs with Rising Residual Current (AC) for Type AC, A/F, B/B+ and EV/MI RCDs (PROFITEST MTECH+, PROFITEST MXTRA only)
- 12.2.2 Testing Systems and RCCBs with Rising Residual Current (AC) for Type B/B+ and EV/MI RCDs (PROFITEST MTECH+PROFITEST MXTRA)
- 12.2.3 Testing RCCBS with 5 × IDN
- 12.2.4 Testing of RCCBs which are Suitable for Pulsating DC Residual Current
- 12.3 Testing of Special RCDs
- 12.4 Testing Residual Current Circuit Breakers in TN-S Systems
- 12.5 Testing of RCD Protection in IT Systems with High Cable Capacitance (e.g. In Norway)
- 12.6 Testing of 6 mA Residual Current Devices RDC-DD/RCMB (RDC-DD: PROFITEST MXTRA and PROFITEST MTECH+ only)
- 13 Testing of Breaking Requirements for Overcurrent Protective Devices, Measurement of Loop Impedance and Determination of Short-Circuit Current (ZL-PE and ISC Functions)
- 14 Measuring Supply Impedance (ZL-N Function)
- 15 Earthing Resistance Measurement (Function RE)
- 15.1 Earthing Resistance Measurement – Mains Powered
- 15.2 Earthing Resistance Measurement – Battery Powered, “Battery Mode” (PROFITEST MPRO & PROFITEST MXTRA only)
- 15.3 Earthing Resistance, Mains Powered – 2-Pole Measurement with 2-Pole Adapter or Country-Specific Plug (Schuko) without Probe
- 15.4 Earthing Resistance Measurement. Mains Powered – 3-Pole Measurement: 2-Pole Adapter with Probe
- 15.5 Earthing Resistance Measurement, Mains Powered – Measuring Earth Electrode Potential (UE Function)
- 15.6 Earthing Resistance Measurement, Mains Powered – Selective Earthing Resistance Measurement with Current Clamp Sensor as Accessory
- 15.7 Earthing Resistance Measurement, Battery Powered, “Battery Mode” – 3-Pole (PROFITEST MPRO & PROFITEST MXTRA only)
- 15.8 Earthing Resistance Measurement, Battery Powered, “Battery Mode” – 4-Pole (PROFITEST MPRO & PROFITEST MXTRA only)
- 15.9 Earthing Resistance Measurement, Battery Powered, “Battery Mode” – Selective (4-pole) with Current Clamp Sensor and PRO-RE Measuring Adapter as Accessory (PROFITEST MPRO & PROFITEST MXTRA only)
- 15.10 Earthing Resistance Measurement, Battery Powered, “Battery Mode” – Ground Loop Measurement (with current clamp sensor and transformer, and pro-re measuring adapter as accessory) (PROFITEST MPRO & PROFITEST MXTRA only)
- 15.11 Earthing Resistance Measurement, Battery Powered, “Battery Mode” – Measurement of Soil Resistivity rE (PROFITEST MPRO & PROFITEST MXTRA only)
- 16 Measurement of Insulation Resistance
- 17 Measuring Low-Value Resistance of up to 200 W (Protective Conductor and Equipotential Bonding Conductor)
- 18 Measurement with Accessory Sensors
- 19 Special Functions – EXTRA Switch Position
- 19.1 Voltage Drop Measurement (at ZLN) – DU Function
- 19.2 Measuring the Impedance of Insulating Floors and Walls (standing surface insulation impedance) – ZST Function
- 19.3 Testing Meter Startup with Earthing Contact Plug – kWh Function
- 19.4 Leakage Current Measurement with PRO-AB Leakage Current Adapter as Accessory – IL Function (PROFITEST MXTRA only)
- 19.5 Testing Insulation Monitoring Devices – IMD Function (PROFITEST MXTRA only)
- 19.6 Residual Voltage Test – Ures Function (PROFITEST MXTRA only)
- 19.7 Intelligent Ramp – ta+ID Function (PROFITEST MXTRA only)
- 19.8 Testing Residual Current Monitors – RCM Function ( PROFITEST MXTRA only)
- 19.9 Checking the Operating Statuses of Electric Vehicles at Charging Stations per IEC 61851 ((PROFITEST MTECH+ & PROFITEST MXTRA)
- 19.10 PRCD – Test Sequences for Documenting Fault Simulations at PRCDs with the PROFITEST PRCD Adapter (PROFITEST MXTRA only)
- 20 Test Sequences (Automatic Test Sequences) – AUTO Function
- 21 Maintenance
- 22 Contact, Support and Service
- 23 CE Declaration
- 24 Disposal and Environmental Protection
- 25 Appendix
- 25.1 Tables for Determining Maximum and Minimum Display Values in Consideration of the Instrument’s Maximum Measuring and Intrinsic Uncertainties
- 25.2 At which values should/must an RCD actually be tripped? Requirements for Residual Current Devices (RCD)
- 25.3 Testing Electrical Machines per DIN EN 60 204 – Applications, Limit Values
- 25.4 Periodic Testing per DGUV V 3 (previously BGV A3) – Limit Values for Electrical Systems and Operating Equipment
- 25.5 Bibliography
- 25.6 Internet Addresses for Additional Information
Gossen Metrawatt GmbH 19
Connection Test — Battery Powered Earthing Resistance Measurements, “Battery Mode”
PE Test via Finger Contact at the Contact Surfaces on the Test Plug
Status bar: Display of Charge Level, Memory Occupancy
Status
Test
Plug
Mea-
suring
Adapter
Function
Switch Position
Function/Meaning
Is displayed
R
E
Standard display without connection messages
Is displayed
PRO-RE
R
E
Interference voltage at probe S > 3 V
Restricted measuring accuracy
Is displayed
Clamp
meter
R
E
Interference/measuring current ratio > 50 at R
E(sel)
, 1000 at R
E(2Z)
Restricted measuring accuracy
at R
E(sel):
Interference current > 0 85 A or interference/measuring current ratio > 100
➭ No measured value, display: RE.Z – – –
Is displayed
PRO-RE
R
E
Probe H not connected or R
E.H
>150k
➭ No measurement, display: RE – – –
R
E.H
> 50 k or
R
E.H
/R
E
> 10000
➭ Measured value is displayed, restricted measuring accuracy
Is displayed
PRO-RE
R
E
Probe S not connected
or R
E.S
> 150 k
or R
E.S
× R
E.H
> 25 M²
➭ No measurement, display: RE – – –
R
E.S
> 50 k or
R
E.S
/R
E
> 300
➭ Measured value is displayed, restricted measuring accuracy
Is displayed
PRO-RE
R
E
Probe E not connected or R
E.E
> 150 kR
E.E
/R
E
> 2000
➭ No measurement, display: RE – – –
R
E.E
/R
E
>300
➭ Measured value is displayed, restricted measuring accuracy
N
PE
L
Status
Test
Plug
Mea-
suring
Adapter
Function Switch
Position
Function/Meaning
LCD LEDs
Is displayed
UL/RL
FI/RCD
light up
red
XX
U
(single-phase
measurement)
Potential difference 50 V between finger contact and PE (earth contact)
Frequency f 50 Hz
Is displayed
U
L
/R
L
FI/RCD
light up
red
XX
U
(single-phase
measurement)
If L is correctly contacted and PE is interrupted (frequency f 50 Hz)
PE
PE
Status
Test
Plug
Mea-
suring
Adapter
Function Switch
Position
Function/Meaning
Battery
status
Is dis-
played
U,
R
INS
,
R
LO
, R
E
,
Z
L-N
, Z
L-PE
,
I
F
, I
N
,
Setup,
EXTRA,
SENSOR
Battery charge level ≥ 80%
Is dis-
played
Battery charge level ≥ 50%
Is dis-
played
Battery charge level ≥ 30%
Is dis-
played
Battery charge level ≥ 15%
Is dis-
played
Battery charge level ≥ 0%