Datasheet

PROFITESTMASTER SERIES
PROFITESTMTECH+, MPRO, MXTRA, MBASE+
IEC 60364-6, EN 50110-1
16 Gossen Metrawatt GmbH
PRO-AB Leakage Current Measuring Adapter (Z502S)
For PROFITEST MXTRA
Input current:
0 … 10 mA
Input impedance:
1 k 0.5%
Output voltage:
10:1: 0 … 1 V (0.1 V/mA)
1:1: 0 … 10 V (1 V/mA)
Output impedance: 10 k
ISO Calibrator 1 (M662A)
Calibration adapter for rapid, effi-
cient testing of the accuracy of
measuring instruments for insula-
tion resistance and low-value
resistors
KS24 Cable Set (GTZ3201000R0001)
The KS24 cable set
includes a 4 m long exten-
sion cord with a perma-
nently attached test probe
at one end and a contact
protected socket at the
other end, as well as an
alligator clip which can be
plugged onto the test
probe.
Telescoping Rods TELEARM 120 (Z505C) and TELEARM 180 (Z505D)
TELEARM Case (Z505E)
1081 Floor Probe (GTZ3196000R0001)
The 1081 floor probe makes it
possible to measure the resis-
tance of insulating floors in
accordance with IEC 60364-6
and EN 1081.
Current Clamp Sensor WZ12C
(Z219C)
Current clamp sensor for
leakage current,
selectable measuring ranges:
1 mA … 15 A, 3%
and 1 A … 150 A, 2%
Transformation ratios:
1 mV/mA, 1 mV/A
METRAFLEX P300 (Z502E)
Flexible current clamp sensor
for selective earthing resis-
tance measurement
3/30/300 A,
1 V/100 mV/10 mV/A
Earth Measurement Accessories
PRO-RE/2 Clamp Adapter (Z502T)
Adapter which is mounted to
the test plug allowing for con-
nection of the E-Clip 2 gener-
ator clamp for 2-clamp or
ground-loop earthing resis-
tance measurement.
2-clamp or ground loop mea-
surement is thus made possi-
ble.
PRO-RE Adapter (Z501S)
Earth electrodes, auxiliary
earth electrodes, probe and
auxiliary probe are connected
to the tester via the banana
plug sockets, and thus via the
adapter which is mounted to
the test plug.
E- CLIP 2 Clamp Generator (Z591B)
Measuring range: 0.2 A …
1200 A
Measuring category: 600 V CAT III
Max. cable diameter: 52 mm
Transformation ratio: 1000A/1A
Frequency range:
40 Hz … 5 kHz
Output signal: 0.2 mA … 1.2 A
Equipped with laboratory safety plug inputs
AC Current Clamp Sensor (Z3512A)
Switchable measur-
ing ranges:
1 mA … 1/100/
1000 A~
Transmission
ratios:
1 V/A, 100 mV/A,
10 mV/A; 1 mV/A