User manual

GMC-I Messtechnik GmbH 13
8 Characteristic Values
Measurement with METRACLIP 61 as Acces-
sory
Protective conductor
current measurement
Measuring range:
0 ... 30 mA AC
Measurements with PROFITEST MXTRA as
accessory:
Protective conductor
measurement Measuring range:
0.1 Ω ... 6 Ω,
see technical data on
R
LO
function of the
PROFITEST MXTRA
Insulation
measurement Measuring range:
50 kΩ ... 500 MΩ,
see technical data on
R
ISO
function of the
PROFITEST MXTRA
Connections
Test outlets
Earth contact
IN4:
1P+N+PE, 0.8 A, 230 V
3P+N+PE IN2/OUT2:
0.8 A, 400 V
Power Supply
Nominal line voltage 230/400 V 50 Hz
Mains connection
Single-phase via inlet
socket:
230 V 1P+N+PE 16 A
or
3-phase via ISO
adapter:
230/400 V 3P+N+PE
16 A
Throughput rating Earth contact: 20 VA
CEE: 60 VA
Power consumption
Earth contact: < 3 VA
CEE: < 6 VA
Electrical Safety
Measuring category 300 V CAT II
Pollution degree 2
Fuse links Supply network:
Single-phase (N1):
F
LN
: 2 ea. F0-8A/
250V, 5 x 20 mm
3-phase (N2):
F1, F2 and F3:
3 ea. F0.8A/500V,
6.3 x 32 mm
Ambient Conditions
Operating temperature
-5 ... + 50°C
Storage temperature -20 ... + 60°C
Relative humidity
Max. 75%, no con-
densation allowed
Mechanical Design
Test adapter
protection IP 40 per DIN VDE
0470, part 1, con-
nections: IP 20
Dimensions Housing (WxHxD):
approx. 401 x 307 x
173 mm
(without con-
nector cable, with sur-
face mount sockets)
Weight Approx. 4.6 kg (with
connector cable)
PROFITESTEMOBILITY Characteristic Values