Datasheet

PROFITESTEMOBILITY
Adapter for Standards-Compliant Testing
of Single and 3-Phase, Mode 2 and 3 Charging Cables
2 GMC-I Messtechnik GmbH
Applicable Regulations and Standards
Characteristic Values
Measurement with METRACLIP 61 as Accessory
Protective conductor current measurement
Measuring range: 0 ... 30 mA AC
Measurements with PROFITEST MXTRA as accessory:
Protective conductor
measurement Measuring range: 0.1 Ω ... 6 Ω,
see technical data on R
LO
function
of the PROFITEST MXTRA
Insulation
measurement Measuring range: 50 kΩ ... 500 MΩ,
see technical data on R
ISO
function
of the PROFITEST MXTRA
Connections
Test outlets
Earth contact IN4:
1P+N+PE, 0.8 A, 230 V
3P+N+PE IN2/OUT2:
0.8 A, 400 V
Power Supply
Nominal line voltage 230/400 V 50 Hz
Mains connection
Single-phase via recessed power receptacle:
230 V 1P+N+PE 16 A
or
3-phase via ISO adapter:
230/400 V 3P+N+PE 16 A
Throughput rating Earth contact: 20 VA
CEE: 60 VA
Power consumption
Earth contact: < 3 VA
CEE: < 6 VA
Electrical Safety
Measuring category 300 V CAT II
Pollution degree 2
Fuse links Supply network:
Single-phase (N1):
F
LN
: 2 ea. F0-8A/250V, 5 x 20 mm
3-phase (N2):
F1, F2 and F3:
3 ea. F0.8A/500V, 6.3 x 32 mm
Ambient Conditions
Operating temperature
-5 ... + 50°C
Storage temperature -20 ... + 60°C
Relative humidity
Max. 75%, no condensation allowed
Mechanical Design
Test adap ter
protection IP 40 per DIN VDE 0470, part 1, connec-
tions: IP 20
Dimensions
(W x H x D) Housing:
Approx. 401 x 307 x 173 mm
(without connector cable, with surface mount
sockets)
Weight Approx. 6.4 kg (with connector cable)
Connection and Control Panel View
IEC 61010-1/
DIN EN 61010-1/
VDE 0411-1
Safety requirements for electrical equipment for mea-
surement, control and laboratory use
– General requirements
EN 60529
VDE 0470, part 1
Test instruments and test procedures
Degrees of protection provided by enclosures (IP code)
IEC 61851-1
DIN EN 61851-1
Electric vehicle conductive charging system
– Part 1: General requirements