2 Applications
Please read this important information!
2.1 Intended Use / Use for Intended Purpose
The METRAHIT IM XTRA BT is multimeter, milliohmmeter, insula-
tion measuring instrument, coil tester and data logger in one. The
METRAHIT IM E-DRIVE BT is a multimeter, milliohmmeter, insula-
tion measuring instrument, coil tester and data logger for hybrid
and electric drives. The METRAHIT IM TECH BT is multimeter,
milliohmmeter and data logger in one.
All three are portable instruments which can be held in the hand
while performing measurements. They can be used to perform
the measurements described in these operating instructions and
in the quick reference guide.
Performance characteristics of the individual models: see “Over-
view of Included Features” on page 2.
The multimeter is equipped with an automatic socket blocking
mechanism for your safety, and in order to safeguard your instru-
ment. This mechanism is linked to the rotary switch and only
allows access to those jacks which are actually required for the
selected function. It also prevents the user from turning the rotary
switch to impermissible functions after the measurement cables
have already been plugged in.
Safety of the operator, as well as that of the instrument, is only
assured when it’s used for its intended purpose.
Safety of the operator, as well as that of the instrument, is only
assured when it’s used for its intended purpose.
2.2 Use for Other than Intended Purpose
Using the instrument for any purposes other than those described
in the condensed operating instructions or these instrument oper-
ating instructions is contrary to use for intended purpose.
2.3 Liability and Guarantee
Gossen Metrawatt GmbH assumes no liability for property dam-
age, personal injury or consequential damage resulting from
improper or incorrect use of the product, in particular due to fail-
ure to observe the product documentation. Furthermore, all guar-
antee claims are rendered null and void in such cases.
Nor does Gossen Metrawatt GmbH accept any liability for data
loss.
2.4 Opening the Instrument / Repairs
The instrument may only be opened by authorized, trained per-
sonnel in order to ensure flawless, safe operation and to assure
that the guarantee isn’t rendered null and void. Even original
replacement parts may only be installed by authorized, trained
personnel.
When the instrument is opened, voltage conducting parts may be
exposed. The instrument must be disconnected from the measur-
ing circuit before performing repairs or replacing parts. If repair of
a live, open instrument is required, it may only be carried out by
trained personnel who are familiar with the dangers involved.
Unauthorized modification of the instrument is prohibited.
If it can be ascertained that the instrument has been opened by
unauthorized personnel, no guarantee claims can be honored by
the manufacturer with regard to personal safety, measuring accu-
racy, compliance with applicable safety measures or any conse-
quential damages.
If a guarantee seal is included and it has been damaged or
removed, all guarantee claims are rendered null and void.
2.5 Manufacturer’s Guarantee
All METRAHIT digital multimeters and calibration instruments are
guaranteed for a period of 3 years after date of shipment. The
manufacturer’s guarantee covers materials and workmanship.
Damages resulting from use for any other than the intended pur-
pose or operating errors, as well as any and all consequential
damages, are excluded.
The calibration certificate confirms that the product’s specified
technical data were complied with at the point in time of calibra-
tion. We guarantee compliance with the specified technical data
within the permissible tolerances for a period of 12 months after
delivery.
The guarantee can be extended to 5 years by registering free of
charge on the myGMC portal.
https://www.gmc-instruments.de/services/mygmc/
3 Documentation
3.1 Product Variants
This documentation describes several instrument variants. Func-
tions may be described which are not included in your instrument.
Observe respective variant identification.
Illustrations may differ from your instrument.
3.2 Firmware Version
These operating instructions describe an instrument based on
firmware version 1.005.001.
Complete information concerning your instrument’s firmware ver-
sion and updating can be found in section 6.2.
3.3 Symbols
The following symbols with the meanings listed below are used in
this documentation.
Danger Symbols
Warning concerning a point of danger
(attention, observe documentation!)
Warning concerning dangerous voltage at the measurement
input: U > 15 V AC or U > 25 V DC
Acoustic Warnings
High-voltage warning: > 1000 V (intermittent acoustic signal)
Very high amperage warning: > 1 A (continuous acoustic signal)
User Interface Symbols in the Following Sections
... Scroll through main menu
... Scroll through submenu
Select decimal point,
increase/decrease measuring range
 Increase/decrease value
(test voltage for insulation resistance measurement or
threshold for continuity test)
!