Manual
Table Of Contents
- 1 Safety Instructions
- 2 Applications
- 3 Documentation
- 4 Operating Overview
- 5 Initial Startup
- 6 System Settings
- 6.1 Digital Keyboard
- 6.2 Firmware
- 6.3 Language Selection
- 6.4 Time and Date Settings
- 6.5 Digital Display Settings
- 6.6 Set Display of Leading Zeros
- 6.7 Configuring Password Protection
- 6.8 Viewing the Instrument’s Name
- 6.9 Installing a Functions Expansion
- 6.10 Switching the Instrument Off
- 6.11 Default Settings (instrument reset)
- 7 Control Functions
- 8 Measurements
- 8.1 Enabling Parameter Changes
- 8.2 Insulation Resistance Measurement – RISO Function (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT only)
- 8.3 Inter-Turn Short Circuit Measurement – COIL Function (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE only)
- 8.4 Absorption Index Measurement – DAR (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT only)
- 8.5 Polarization Index Measurement – PI (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT only)
- 8.6 Voltage Measurement
- 8.6.1 Alternating Voltage and Frequency Measurement V AC and Hz with Selectable Low-Pass Filter
- 8.6.2 Duty Cycle Measurement – Duty AC (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT only)
- 8.6.3 RPM Measurement – RPM AC (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT only)
- 8.6.4 Direct and Pulsating Voltage Measurement, V DC and V (AC+DC)
- 8.7 Resistance Measurement “W”
- 8.8 Capacitance Measurement F
- 8.9 Temperature Measurement with Resistance Thermometers – Temp RTD
- 8.10 Temperature Measurement with Thermocouple – Temp TC
- 8.11 Continuity Test
- 8.12 Diode Testing with Constant Current of 1 mA
- 8.13 Milliohm Measurement – Rlo (2-wire measurement) (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE only)
- 8.14 Milliohm Measurement – mW/4 (4-wire measurement)
- 8.15 Current Measurement
- 8.15.1 Direct and Pulsating Current Measurement, Direct Connection, – A DC and A (AC+DC)
- 8.15.2 Alternating Current and Frequency Measurement, Direct Connection, – AAC and Hz
- 8.15.3 Direct and Pulsating Current Measurement with Current Clamp Sensor – ADC und A (AC+DC)
- 8.15.4 Alternating Current Measurement with Current Clamp Sensor – AAC and Hz
- 8.16 Measuring Sequences – Test Sequences
- 9 Interface Operation and Software
- 10 Characteristic Values
- 11 Maintenance and Calibration
- 12 Accessories
- 13 Returns and Environmentally Sound Disposal
- 14 CE Declaration
- 15 Addresses
58 Gossen Metrawatt GmbH
9.2.3 METRALOG App (smartphone and tablet)
If you use a smartphone or a tablet with the Android operating
system and a Bluetooth
®
interface, our METRALOG app provides
the following functions in combination with the multimeter:
• Display of received multimeter measured values as:
Digital or analog values, measured value curve Y(t), measured
value logger
• Recording of measuring operations
• Transmission of logs via wireless services and network ser-
vices
• Acoustic warning in the event that wireless connection is inter-
rupted
• Trigger in the event of exceeding or falling short of an adjust-
able limit value
• Acoustic warning if a trigger event should occur
The METRALOG app can be obtained from the
Google Play Store (see QR code to the right) and
installed. Information regarding installation can be
found at the Google Play Store and in the docu-
mentation for your mobile device.
Complete information on working with the app can be found in its
own online help. Initial steps required after installation and for
operation are described below.
➭ Activate Bluetooth
®
at your measuring instrument.
➭ Tap the app’s icon on the mobile device in order to start the
app.
➭ Select multimeter from the list of receivable Bluetooth devices.
The following message appears: “Connecting to measuring
instrument via Bluetooth”.
➭ In order to enable wireless connection, enter the same PIN
which you also entered under the multimeter’s PIN interface
parameter. After connection has been successfully estab-
lished, an analog display appears and “Measurement com-
pleted” appears at the bottom right.
➭ You can switch back and forth amongst digital display, Y(t)
measured value curve and analog display in the footer at the
left-hand side.
➭ You can start or stop a measured value recording by tapping
the REC symbol.
➭ You can switch the display to the measured value logger over-
view by tapping the magnifying glass icon in the footer at the
right-hand side Measuring intervals can be selected here, in
order to display them graphically or transmit them.
9.2.4 Sequence Manager: Software for Test Sequences
Test sequences (see section 8.16, “Measuring Sequences – Test
Sequences”) can be created and managed at the instrument or in
more convenient Sequence Manager PC software. It provides the
following functions:
• Import/export of sequences to and from a PC and the instru-
ment via Bluetooth
®
• Sequence editing functions:
• Create new sequences
• Add and delete test steps
• Copy and paste test steps
• Change the order of test steps
• Edit comments
• Import/export of sequences as TXT files
Note
Observe the maximum possible number of test
sequences and test steps per instrument!
Standard: 1 sequence with up to 10 steps for the
METRAHIT IM XTRA BT and the METRAHIT IM E-DRIVE
BT, none for the METRAHIT IM TECH BT.
With Sequence Functions Expert: 16 sequences with up to
63 test steps.
Note
Sequences with the identical names are possible!
Multiple sequences with identical names can be created
and managed, as well as imported and exported, at the
instrument and in the program.
In order to avoid confusion, rename or delete the
sequences (see page 59).
Download & Installation
Complete information concerning current software and firmware,
as well as instrument updates and options, can be found in the
myGMC portal. Please register for free, after which you’ll have ac-
cess to the downloads and will always receive the latest informa-
tion about your instrument.
https://www.gmc-instruments.de/services/mygmc/
For the Sequence Manager, download the README.TXT file and the
current Sequence Manager ZIP file.
Attention!
!
Read and adhere to the README.TXT file. It includes all
important information about the program, such as sys-
tem requirements and installation instructions.
➭ Unpack the ZIP file.
➭ Run the installation file.
The installation wizard appears.
➭ Follow the instructions displayed by the installation wizard.
➭ The software is installed on your PC.
Starting the Program
Start the program using the usual procedure for your operating
system.
Attention!
!
Do not start and use the Sequence Manager and the
METRAHIT IM Data Reader at the same time.
The programs interfere with each other’s Bluetooth
®
communication.