Manual
Table Of Contents
- 1 Safety Instructions
- 2 Applications
- 3 Documentation
- 4 Operating Overview
- 5 Initial Startup
- 6 System Settings
- 6.1 Digital Keyboard
- 6.2 Firmware
- 6.3 Language Selection
- 6.4 Time and Date Settings
- 6.5 Digital Display Settings
- 6.6 Set Display of Leading Zeros
- 6.7 Configuring Password Protection
- 6.8 Viewing the Instrument’s Name
- 6.9 Installing a Functions Expansion
- 6.10 Switching the Instrument Off
- 6.11 Default Settings (instrument reset)
- 7 Control Functions
- 8 Measurements
- 8.1 Enabling Parameter Changes
- 8.2 Insulation Resistance Measurement – RISO Function (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT only)
- 8.3 Inter-Turn Short Circuit Measurement – COIL Function (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE only)
- 8.4 Absorption Index Measurement – DAR (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT only)
- 8.5 Polarization Index Measurement – PI (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT only)
- 8.6 Voltage Measurement
- 8.6.1 Alternating Voltage and Frequency Measurement V AC and Hz with Selectable Low-Pass Filter
- 8.6.2 Duty Cycle Measurement – Duty AC (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT only)
- 8.6.3 RPM Measurement – RPM AC (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT only)
- 8.6.4 Direct and Pulsating Voltage Measurement, V DC and V (AC+DC)
- 8.7 Resistance Measurement “W”
- 8.8 Capacitance Measurement F
- 8.9 Temperature Measurement with Resistance Thermometers – Temp RTD
- 8.10 Temperature Measurement with Thermocouple – Temp TC
- 8.11 Continuity Test
- 8.12 Diode Testing with Constant Current of 1 mA
- 8.13 Milliohm Measurement – Rlo (2-wire measurement) (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE only)
- 8.14 Milliohm Measurement – mW/4 (4-wire measurement)
- 8.15 Current Measurement
- 8.15.1 Direct and Pulsating Current Measurement, Direct Connection, – A DC and A (AC+DC)
- 8.15.2 Alternating Current and Frequency Measurement, Direct Connection, – AAC and Hz
- 8.15.3 Direct and Pulsating Current Measurement with Current Clamp Sensor – ADC und A (AC+DC)
- 8.15.4 Alternating Current Measurement with Current Clamp Sensor – AAC and Hz
- 8.16 Measuring Sequences – Test Sequences
- 9 Interface Operation and Software
- 10 Characteristic Values
- 11 Maintenance and Calibration
- 12 Accessories
- 13 Returns and Environmentally Sound Disposal
- 14 CE Declaration
- 15 Addresses
Gossen Metrawatt GmbH 23
Activating the Trigger
The trigger function cannot be set during memory mode opera-
tion.
➭ Press the MENU key.
➭ Press the General Setup softkey.
➭ Select the Memory menu with the
scroll keys.
➭ Switch to the submenu with the help of the
scroll key.
➭ Select the Trigger parameter with the scroll keys.
➭ Acknowledge the selected parameter by pressing the OK key.
➭ Select the respective function (within, outside or off) with the
help of the
scroll keys.
➭ Acknowledge your change with the OK key. The entry cursor
once again marks the entire parameter line.
> General Setup
Memory Trigger
Adjusting the Trigger Threshold
These parameters cannot be set during memory mode operation.
➭ Press the MENU key.
➭ Press the General Setup softkey.
➭ Select the Memory menu with the
scroll keys.
➭ Switch to the submenu with the help of the
scroll key.
➭ Select the Trigger Low Limit or Trigger High Limit parameter with
the help of the scroll keys.
➭ Acknowledge the selected parameter by pressing the OK key.
➭ Select the desired entry position within the parameter using
the
scroll keys and change the respective value with the
scroll keys.
➭ Acknowledge your change with the OK key. The entry cursor
once again marks the entire parameter line.
> General Setup
Memory Trigger Low Limit
+00000 digits / Trigger High Limit +00000 digits
Managing Groups
Groups can be created in order to be able to sort measured val-
ues when they’re saved. The groups can be managed.
➭ Press the MENU key.
➭ Press the General Setup softkey.
➭ Select the Memory menu with the
scroll keys.
➭ Switch to the submenu with the help of the
scroll key.
➭ Select the Groups parameter with the help of the
scroll
keys.
➭ Acknowledge the selected parameter by pressing the OK key.
➭ Manage the groups with the help of the New, Edit and Delete
softkeys.
Entries are made via the digital keyboard (see section 6.1).
> General Setup
Memory Groups
Selecting a Group
Before starting the respective measurement, select a suitable
group from the list you’ve created to which the measured values
will be saved.
➭ Press the MENU key.
➭ Press the General Setup softkey.
➭ Select the Memory menu with the
scroll keys.
➭ Switch to the submenu with the help of the scroll key.
➭ Select the Groups parameter with the help of the
scroll
keys.
➭ Acknowledge the selected parameter by pressing the OK key.
➭ Select the desired group with the
scroll keys.
➭ Acknowledge your selection with the Select softkey.
> General Setup
Memory Groups
Select
7.7.3 Memory
Memory space in the instrument is limited to 300,000 measured
values. You can check memory occupancy and clear memory if
necessary.
Querying Memory Occupancy
You can query memory occupancy from within the “Info” menu
before, as well as during the save operation.
Memory occupancy range: 000.1% ... 099.9%.
> General Setup
Info > Memory Occupancy x.x%
Clearing Memory (deleting measured values)
This function deletes all measured values from memory!
This function cannot be executed during memory mode opera-
tion.
> General Setup
Memory Clear Memory
The following security prompt appears before memory is cleared:
“Clear memory?”. This prompt must be acknowledged with “Yes”
via the function key (not with OK).
Confirmation is displayed at the end of the operation: “Memory
has been cleared.”
MENU
OK
MENU
OK
MENU
MENU
MENU
MENU