Instructions
Table Of Contents
- 1 Safety Features and Precautions
- 2 Operating Overview – Connections, Keys, Rotary Switch, Symbols
- 3 Initial Start-Up
- 4 Control Functions
- 5 Measurements
- 5.1 Voltage Measurement
- 5.1.1 Direct and Pulsating Voltage Measurement, V DC and V (DC+AC)
- 5.1.2 Alternating Voltage Measurement with 1 MW Load Resistance and Frequency Measurement with Selectable Low-Pass Filter (METRA HIT Extra, METRA HIT Etech and METRA HIT Especial only)
- 5.1.3 Alternating Voltage and Frequency Measurement V AC and Hz with Selectable Low-Pass Filter (METRA HIT Extra, METRA HIT Etech and METRA HIT Especial only)
- 5.1.4 Frequency and Duty Cycle Measurements (METRA HIT Extra only)
- 5.2 Resistance Measurement, W
- 5.3 Continuity Test
- 5.4 Diode Testing with a Constant Current of 1 mA
- 5.5 Temperature Measurement
- 5.6 Capacitance Measurement (METRA HIT Extra and METRA HIT Etech only)
- 5.7 Current Measurement
- 5.7.1 Direct and Pulsating Current Measurement, Direct Connection, A DC and A (DC+AC) (METRA HIT Extra, METRA HIT Etech and METRA HIT Especial only)
- 5.7.2 Alternating Current and Frequency Measurement, Direct Connection, A AC and Hz (METRA HIT Extra, METRA HIT Etech and METRA HIT Especial only)
- 5.7.3 Direct and Pulsating Current Measurement with Current Clamp Sensors, A DC and A (DC+AC)
- 5.7.4 Alternating Current Measurement with Current Clamp Sensors, A AC and Hz
- 5.7.5 Direct, Pulsating and Current Measurement with Current Clamps Transformer A DC, A (DC+AC), A AC and Hz (METRA HIT Extra, METRA HIT Etech and METRA HIT Especial only)
- 5.1 Voltage Measurement
- 6 Device and Measuring Parameters
- 7 Interface Operation
- 8 Technical Data
- 9 Maintenance and Calibration
- 10 Accessories
- 11 Index
50 GMC-I Messtechnik GmbH
Device and Measuring Parameters
bEEP – set the limit value for continuity testing
1nFo
... SET rAtE ... bEEP
1, 10, 20 ... 500
(10 = default setting)
irStb – status of the infrared receiver in the stand-by mode
See chapter 7.2 on page 53 regarding settings.
Addr – select device address
See chapter 7.2 on page 53.
dAtE – enter date
Entering the current date makes it possible to acquire measured
values in real-time.
1nFo
... SET rAtE ... dAtE
31.12 (DD: day . MM: month)
2005 (YYYY: year)
Date and time must be reentered after replacing the batteries.
tiME – set time
Entering the correct time makes it possible to acquire measured
values in real-time.
1nFo ... SET rAtE ... t iME
10:24 (hh:mm)
Date and time must be reentered after replacing the batteries.
CLIP – set transformation factor
See chapter 5.7.3 ff.
MEASURE
SETUP
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
MEASURE
SETUP
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
MEASURE
SETUP
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER