User Manual
Table Of Contents
- 1 Safety Features and Precautions
- 2 Operating Overview – Connections, Keys, Rotary Switch, Symbols
- 3 Initial Start-Up
- 4 Control Functions
- 5 Measurements
- 5.1 Voltage Measurement
- 5.1.1 Direct and Pulsating Voltage Measurement, V DC and V (DC+AC)
- 5.1.2 Alternating Voltage Measurement with 1 MW Load Resistance and Frequency Measurement with Selectable Low-Pass Filter (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.1.3 Alternating Voltage and Frequency Measurement V AC and Hz with Selectable Low-Pass Filter (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.1.4 Frequency and Duty Cycle Measurements (METRA HIT AM XTRA / Outdoor / SECULIFE HITam/md only)
- 5.2 Resistance Measurement, W
- 5.3 Continuity Test
- 5.4 Diode Testing with a Constant Current of 1 mA
- 5.5 Temperature Measurement
- 5.6 Capacitance Measurement (METRA HIT AM XTRA / Outdoor / SECULIFE HITam/md and METRA HIT AM TECH only)
- 5.7 Current Measurement
- 5.7.1 Direct and Pulsating Current Measurement, Direct Connection, A DC and A (DC+AC) (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.7.2 Alternating Current and Frequency Measurement, Direct Connection, A AC and Hz (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.7.3 Direct and Pulsating Current Measurement with Current Sensor Clamp, A DC and A (DC+AC)
- 5.7.4 Alternating Current Measurement with Current Sensor Clamp A AC and Hz
- 5.7.5 Direct, Pulsating and Current Measurement with Current Transformer Clamp A DC, A (DC+AC), A AC and Hz (not METRA HIT AM BASE)
- 5.1 Voltage Measurement
- 6 Device and Measuring Parameters
- 7 Interface Operation (METRA HIT AM XTRA / Outdoor / SECULIFE HITam/md only)
- 8 Technical Data
- 9 Maintenance and Calibration
- 10 Accessories
- 11 Index
GMC-I Messtechnik GmbH 55
Technical Data
2)
At 0 ... + 40 C
6)
Applies to measurements at film capacitors and during battery operation
7)
Lowest measurable frequency for sinusoidal measuring signals symmetrical to the zero point
8)
Overload capacity of the voltage measurement input:
power limiting: frequency x voltage, max. 3 x 10
6
V x Hz for U > 100 V
9)
Overload capacity of the current measurement input:
See current measuring ranges for maximum current values.
10)
Input sensitivity, sinusoidal signal, 10% to 100% of the measuring range
11)
Plus sensor deviation
Key: R = meas. range, d = digit(s), rdg. = measured value (reading)
Meas.
Function
Measuring Range
Resolution at Upper
Range Limit
Input impedance
Intrinsic Error under Reference Conditions
Overload Capacity
2)
11,999 1199 ~ / Value Time
Discharge resistance U
0 max
(... % rdg. + ... d)
F
AM XTRA
O
UTDOOR
AM TECH
10 nF 10 pF 10 M 0.7 V 1 + 6
6)
with ZERO function active
1000 V
DC
AC
RMS
Sine
Max. 10 s
100 nF 100 pF 1 M 0.7 V 1 + 6
6)
1 F 1 nF 100 k 0.7 V 1 + 6
6)
10 F10nF12k 0.7 V 1 + 6
6)
100 F 100 nF 3 k 0.7 V 5 + 6
6)
1000 F1F3k 0.7 V 5 + 6
6)
f
min
7)
(... % rdg. + ... d)
Hz (V)
Hz (A)
Hz (A )
100.00 Hz 0.01 Hz
1Hz
0.05 + 3
10)
Hz (V)
8)
:
Hz(A )
8)
:
1000 V
Hz (A):
9
)
Max. 10 s
1.0000 kHz 0.1 Hz
10.000 kHz 1 Hz
Hz (V)
100.00 kHz 10 Hz 10 Hz
Hz (A)
30.00 kHz 10 Hz 10 Hz
MHz
AM XTRA
O
UTDOOR
100 Hz ... 1 MHz
0.01 ...
100 Hz
1 ... 100 Hz 0.05 + 3 > 2 V ... 5 V
1000 V Max. 10 s
%
AM XTRA
O
UTDOOR
2.0 ... 98% — 0.01% 15 Hz ... 1 kHz 0.1 R per kHz > 2 V ... 5 V
5.0 ... 95% — 0.01% 1 kHz... 10 kHz 0.1 R per kHz > 2 V ... 5 V
10... 90% — 0.01% 10 kHz... 100 kHz 0.1 R per kHz > 2 V ... 5 V
(... % rdg. + ... d)
C/F
Pt 100
AM XTRA
O
UTD
.
– 200.0 ...
+850.0 C
0.1 C
0.3 + 15
11)
1000 V
DC/AC
RMS
Sine
Max. 10 s
Pt 1000
AM XTRA
O
UTD
.
– 150.0 ...
+850.0 C
0.3 + 15
11)
K
(NiCr-Ni)
– 250.0 ...
+1372.0 C
1% + 5 K
11)