User Manual
Table Of Contents
- 1 Safety Features and Precautions
- 2 Operating Overview – Connections, Keys, Rotary Switch, Symbols
- 3 Initial Start-Up
- 4 Control Functions
- 5 Measurements
- 5.1 Voltage Measurement
- 5.1.1 Direct and Pulsating Voltage Measurement, V DC and V (DC+AC)
- 5.1.2 Alternating Voltage Measurement with 1 MW Load Resistance and Frequency Measurement with Selectable Low-Pass Filter (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.1.3 Alternating Voltage and Frequency Measurement V AC and Hz with Selectable Low-Pass Filter (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.1.4 Frequency and Duty Cycle Measurements (METRA HIT AM XTRA / Outdoor / SECULIFE HITam/md only)
- 5.2 Resistance Measurement, W
- 5.3 Continuity Test
- 5.4 Diode Testing with a Constant Current of 1 mA
- 5.5 Temperature Measurement
- 5.6 Capacitance Measurement (METRA HIT AM XTRA / Outdoor / SECULIFE HITam/md and METRA HIT AM TECH only)
- 5.7 Current Measurement
- 5.7.1 Direct and Pulsating Current Measurement, Direct Connection, A DC and A (DC+AC) (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.7.2 Alternating Current and Frequency Measurement, Direct Connection, A AC and Hz (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.7.3 Direct and Pulsating Current Measurement with Current Sensor Clamp, A DC and A (DC+AC)
- 5.7.4 Alternating Current Measurement with Current Sensor Clamp A AC and Hz
- 5.7.5 Direct, Pulsating and Current Measurement with Current Transformer Clamp A DC, A (DC+AC), A AC and Hz (not METRA HIT AM BASE)
- 5.1 Voltage Measurement
- 6 Device and Measuring Parameters
- 7 Interface Operation (METRA HIT AM XTRA / Outdoor / SECULIFE HITam/md only)
- 8 Technical Data
- 9 Maintenance and Calibration
- 10 Accessories
- 11 Index
GMC-I Messtechnik GmbH 27
V/Hz, , Temperature, and A/Hz Measurements
5.1.1 Direct and Pulsating Voltage Measurement, V DC and V (DC+AC)
Note
(This not does not apply to METRAHITAM BASE)
Set the CL iP parameter to 0FF in the current clip setup menu.
Otherwise all measured values are displayed in amperes,
and are corrected by the amount resulting from the selected
transformation ratio for an interconnected current sensor
clamp.
1nFo
... SET rAtE ... CL IP
1 / 10/100/1000 / 0ff
➭ In accordance with the voltage to be measured, turn the rotary
switch to V or V
.
➭ Connect the measurement cables as shown.
The “” connector jack should be grounded.
Note
An intermittent acoustic signal warns the operator if the mea-
sured value exceeds the upper range limit in the 1000 V range.
Make sure that a current measuring range (“A”) has not been
activated when the multimeter is connected for voltage measure-
ment! If the fuse’s blowing limits are exceeded as a result of oper-
ator error, both the operator and the instrument are in danger!
With the rotary switch in the V position, the multimeter is always
set to the 1 V measuring range immediately after it is switched on.
As soon a the MAN / AUTO key is pressed, and assuming the
measured value is less than 90 mV, the multimeter is switched to
the mV measuring range.
MEASURE
SETUP
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
COM
V
Temp
– (+)
+ (–)
V= : 100 mV1000 V
020
.
00
V
DC
AC
TRMS
020
.
00
V
DC
V
V
V
V
> 55 V AC or > 70 V DC:
> 1000 V:
Warnings regarding dangerous voltage:
Max. 1000 V (< 10 kHz)
V: 100 mV1000 V
Hz: 1Hz 100 kHz
Max. 100 V (> 10 kHz)
P
max
= 3 x 10
6
V x Hz
Measuring Ranges:
230
.
0
FUNC
ENTER
for U > 100 V