User Manual
Table Of Contents
- 1 Safety Features and Precautions
- 2 Operating Overview – Connections, Keys, Rotary Switch, Symbols
- 3 Initial Start-Up
- 4 Control Functions
- 5 Measurements
- 5.1 Voltage Measurement
- 5.1.1 Direct and Pulsating Voltage Measurement, V DC and V (DC+AC)
- 5.1.2 Alternating Voltage Measurement with 1 MW Load Resistance and Frequency Measurement with Selectable Low-Pass Filter (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.1.3 Alternating Voltage and Frequency Measurement V AC and Hz with Selectable Low-Pass Filter (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.1.4 Frequency and Duty Cycle Measurements (METRA HIT AM XTRA / Outdoor / SECULIFE HITam/md only)
- 5.2 Resistance Measurement, W
- 5.3 Continuity Test
- 5.4 Diode Testing with a Constant Current of 1 mA
- 5.5 Temperature Measurement
- 5.6 Capacitance Measurement (METRA HIT AM XTRA / Outdoor / SECULIFE HITam/md and METRA HIT AM TECH only)
- 5.7 Current Measurement
- 5.7.1 Direct and Pulsating Current Measurement, Direct Connection, A DC and A (DC+AC) (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.7.2 Alternating Current and Frequency Measurement, Direct Connection, A AC and Hz (METRA HIT AM X-TRA / AM TECH / AM PRO / Outdoor / SECULIFE HITam/md only)
- 5.7.3 Direct and Pulsating Current Measurement with Current Sensor Clamp, A DC and A (DC+AC)
- 5.7.4 Alternating Current Measurement with Current Sensor Clamp A AC and Hz
- 5.7.5 Direct, Pulsating and Current Measurement with Current Transformer Clamp A DC, A (DC+AC), A AC and Hz (not METRA HIT AM BASE)
- 5.1 Voltage Measurement
- 6 Device and Measuring Parameters
- 7 Interface Operation (METRA HIT AM XTRA / Outdoor / SECULIFE HITam/md only)
- 8 Technical Data
- 9 Maintenance and Calibration
- 10 Accessories
- 11 Index
12 GMC-I Messtechnik GmbH
Operating Overview – Connections, Keys, Rotary Switch, Symbols
2
Operating Overview – Connections, Keys, Rotary Switch, Symbols
1 Display (LCD) (see page 13 for significance of symbols)
2 MAN / AUTO shift key for manual/automatic measuring range selection
Increase parameter values
Operating mode menu:
Select individual menu entries against direction of flow
3
ON / OFF | LIGHT
key for switching device and display illumination on and off
4 FUNC | ENTER multifunction key
Operating mode menu: Acknowledge entry (ENTER)
5
Increase measuring range or move decimal point to the right (MAN function)
6
Rotary switch
for measuring functions, (see page 15 for significance of symbols)
7 DAkkS calibration mark
8 Connector socket for ground
9 Connector socket for current measurement with automatic blocking
10 Connector socket for voltage, resistance, temperature, diode
and
capacitance measurement (
METRAHIT AM XTRA / O
UTDOOR
,
METRAHIT
AM TECH and
SECULIFEHIT
AM
/
MD
only) with automatic blocking
11 DATA / MIN / MAX
Key for freezing, comparing and deleting measured value, and for Min/Max
Decrease values
Operating mode menu: Select individual menu entries in direction of flow
12 MEASURE | SETUP
Key for switching back and forth between measuring and menu function
13 ZERO | ESC
Key for zero balancing
Operating mode menu: Exit current menu level and return to a higher
level, exit parameters configuration without
saving data
14
Decrease measuring range or move decimal point to the left (MAN function)
15 Connector for power pack *
16 Infrared interface *
* METRAHIT AM XTRA / OUTDOOR / SECULIFEHITAM/MD only
* METRAHIT AM BASE:
Current measurement by means of current sensor clamp with voltage output only
1
3
4
16
5
6
9
*
*
chapter 4.3
chapter 3
chapter 5
chapter 7
chapter 6
chapter 3
ff.
chapter 3
14
12
chapter 4.1
10
2
chapter 4.1.2
15
8
12
15
chapter 4.1
chapter 4.4
chapter 6
chapter 3
chapter 3.1
7
chapter 1.2
chapter 6
max. 1000 V ! / SECULIFE HITAM & MD: max. 600 V !