Datasheet

Edited in Germany • Subject to change without notice • A pdf version is available on the internet
METRAmax
3
Analog Multimeter
GMC-I Messtechnik GmbH
Südwestpark 15
90449 Nuremberg •
Germany
Phone +49 911 8602-111
Fax +49 911 8602-777
E-Mail info@gossenmetrawatt.com
www.gossenmetrawatt.com
Display
Scale Length approx. 87 mm
Pointer Stop 0 100
Accuracy Class 2.5 for zero-frequency and periodic
quantities, and resistance
Reference Conditions
Ambient Temperature +23 C 3 C
Relative Humidity 40% 50%
Measured Quantity
Frequency 45 Hz 65 Hz
Measured Quantity
Waveshape sine, 1% max deviation
Battery Voltage 1.5 V
Position of Use horizontal
Ambient Conditions
Accuracy 0 C +40 C
Storage Temperature 25 C +65 C (without batteries)
Relative Humidity max. 75%, no condensation allowed
Elevation to 2000 m
Electrical Safety
•All current measuring ranges are protected with a 230 V circuit
breaker. Resistance measuring ranges are protected with PTC
thermistors. In order to comply with the latest safety regula-
tions (IEC/EN 611010-1), a 16 A / 500 V slow-blow V1 fuse
connected in series to the tripping contact is used for protec-
tion with voltages of up to 600 V.
•The voltage measuring ranges are protected with appropriately
dimensioned power resistors.
Contamination Degree
2
Test Voltage 3700 V, 50/60 Hz, 1 min
Electromagnetic Compatibility (EMC)
Interference emission EN 61326-1:2006, class B
Interference immunity EN 61326-1:2006
EN 61326-2-1:2006
Power Supply
1.5 V mignon cell for resistance measurement
zinc-carbon battery per IEC R6 or
alkaline-manganese battery per IEC LR 6
Mechanical Design
Protection housing: IP 40 per EN 60529
Extract from table on the meaning of IP codes
Dimensions 104 mm x 143 mm x 40 mm
Weight approx. 0.3 kg with batteries
Standard Equipment
1 multimeter (without cable set)
1battery
1operating instructions
Guarantee
1 year for material and workmanship
Order Information
For additional information concerning accessories, please refer to
our Measuring Instruments and Testers Catalog
our website www.gossenmetrawatt.com
Voltage Current
Measuring Category II III II
Operating Voltage 600 V 300 V 240 V AC/50 V DC
IP XY
(1
st
digit X)
Protection against
foreign object entry
IP XY
(2
nd
digit Y)
Protection against the
penetration of water
4 1,0 mm dia. 0 not protected
Description Type Article Number
Analog multimeter with circuit
breaker METRAmax
3 M103A
Carrying pouch F841 Z104A
Protective rubber cover GH19 Z104B
Cable set (1 pair of measurement
cables) 1.2 m, with VDE-GS symbol
(600 V CAT III 16 A) KS17-ONE Z110K
Cable set (1 pair of measurement
cables) 1.2 m, with VDE-GS symbol
(1000 V CAT III / 600 V CAT IV 16 A) KS17-2 GTY3620034P0002