1.6 Menus
1.6.1 Main Menu
Press key to enter into main menu. Please see the list below for main menu content:
List of available functions and parameters:
Note
Except knob, key sound and interface configurations, the other parameters in main menu will not be saved when the load is
turned off. If it is needed to save the parameters, please use
key and key or *sav command. When the load is turned
on next time, the saved parameters in location 0 will be recalled automatically.
1.6.2 Mode Selection and Parameter Setting Menu
Press key to enter into mode selection and parameter setting menu, which is shown as below:
Function/Parameter Description
Load Default
Yes *No
Restore default
Yes *No
Short
On *Off
Short circuit mode
On *Off
Von Latch
On *Off
Von Latch
On *Off
Von Point
0.000v
Set Von voltage point
Von point
CV Curr Limit
40.00A
Current limit in CV mode
Current limit
Curr Rise Rate
4,000A/us
Current rise rate in CC mode
Current rise rate
Curr Fall Rate
4,000A/us
Current fall rate in CC mode
Current fall rate
Trig Function
*Tran List
Trigger function selection
Transient test Sequence test (list)
Knob
On *Off
Enable/disable knob function
On *Off
Key Sound
On *Off
Enable/disable key sound
On *Off
Interface
*RS232 USB GPIB
Remote interface selection
RS232 USB GPIB
RS232 interface Baud rate
2400 4800 *9600 19200 38400
Baud rate setting
2400 4800 9600 19200 38400
Parity Check
*None Even Odd
Parity check setting
None Even Odd
Data Bit
*8 7
Data bits length
8bits 7bits
Stop Bit
*1 2
Stop bit length
1bit 2bits
Flow Control
On *Off
Enable/disable flow control
On *Off
USB interface USB selection
GPIB interface GPIB address
5
GPIB address
Address value
Function / Parameter Description
MODE : CCL
CURR : 0.000A
Constant current low range
Immediate current level
MODE : CCH
CURR : 0.000A
Constant current high range
Immediate current level
MODE : CV
VOLT : 80.00V
Constant voltage mode
Immediate voltage level
MODE : CRL
RES : 2.000
Ω
Constant resistance low range
Immediate resistance level
MODE : CRM
RES : 20.000
Ω
Constant resistance medium range
Immediate resistance level
MODE : CRH
RES : 20.000
Ω
Constant resistance high range
Immediate resistance level
MODE : CPV
POWR : 0.000W
Constant power-voltage source mode
Immediate power level